Swing Motors
Step
4
Remove the swing
motor unit.
5
Detach the interlock
shaft from the swing
motor with a flat
screwdriver.
6
Remove the vertical
blade interlock with a
flat screwdriver.
7
Remove the 2 screws
and remove the swing
motor for vertical
blades.
14
Procedure
Interlock shaft
Interlock shaft
Vertical blade interlock
Swing motor for vertical blades
Swing motor unit
(R21144)
(R8127)
(R10331)
Screw
(R21145)
Si041252EE