JRC ECDIS Instruction Manual page 170

Table of Contents

Advertisement

Message
Bow Azimuth Thruster
#n (not plausible)
Bow Azimuth Thruster
#n (unavailable)
Bow Thruster #n (invalid) There is a format error or
Bow Thruster #n (not
plausible)
Bow Thruster #n
(unavailable)
Current(Communication
failed, Main LAN)
Current(Communication
failed, Sub LAN)
Current(invalid)
Current(not plausible)
Current(unavailable)
DATUM(unavailable)
Depth(invalid)
Depth(unavailable)
Draft(invalid)
Draft(not plausible)
Draft(unavailable)
Appendix A Alert and Maintenance INFO List
Explanation
There is a range error of
the data.
The data cannot be
received.
a status error of the data.
There is a range error of
the data.
The data cannot be
received.
Communication with tidal
current meter cannot be
performed via Main LAN.
Communication with tidal
current meter cannot be
performed via Sub LAN.
There is a format error or
a status error of the Tidal
Current data.
There is a range error of
Tidal Current data.
The Tidal Current data
cannot be received.
The DTM data cannot be
received.
There is a format error or
a status error of the Depth
data.
The Depth data cannot be
received.
There is a format error or
a status error of the data.
There is a range error of
the data.
The data cannot be
received.
A-18
Advice
Check the sensor condition.
Check the condition of the sensor and the
communication path.
Check the sensor condition.
Check the sensor condition.
Check the condition of the sensor and the
communication path.
"Check the condition of tidal current meter
and Main LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor."
"Check the condition of tidal current meter
and Sub LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor."
Check the sensor condition. Switch to a
sensor in good condition, if available.
Check the sensor condition. Switch to a
sensor in good condition, if available.
Check the condition of the sensor and the
communication path. Switch to a sensor in
good condition, if available.
Check the condition of the sensor and the
communication path. Switch to a sensor in
good condition, if available.
Check the sensor condition. Switch to a
sensor in good condition, if available.
Check the condition of the sensor and the
communication path. Switch to a sensor in
good condition, if available.
Check the sensor condition.
Check the sensor condition.
Check the condition of the sensor and the
communication path.