Storage & Service; Specifications - Tripp Lite SmartPro XL INT 2200 Owner's Manual

Intelligent, line-interactive ups systems (230v)

Advertisement

External Battery Connector
Use to connect additional Tripp Lite battery packs for additional
runtime. Refer to the label next to the connector for the appro-
priate Tripp Lite battery pack to connect. Refer to instructions
available with the battery pack for complete connection informa-
tion and safety warnings.
Storage & Service
Storage
Turn your UPS OFF: first engage the ON/Standby Switch and release it to place
your UPS in the "Standby" mode, then move the System Enable Switch to the
"DISABLE" (DOWN) position to prevent battery drain, then disconnect the UPS
power cord from the wall outlet. If you plan on storing your UPS for an extended
period of time, recharge the UPS batteries once every three months. Follow
steps #1 and #3 in the Quick Installation section and allow the UPS to charge
from 4 to 6 hours. If you leave your UPS batteries discharged for an extended
period of time, they will suffer permanent loss of capacity.
Service
If returning your UPS for service, contact your local Tripp Lite dealer or
distributor. They will refer you to a service center. Please carefully pack the UPS
using the ORIGINAL PACKING MATERIAL that came with the unit. Enclose a
letter describing the symptoms of the problem. If the UPS is within the 2 year
warranty period, enclose a copy of your sales receipt.

Specifications

Output Capacity (VA/Watts):
Battery Runtime (Half Load/
Full Load) Minutes:
Battery Recharge Time:
Approvals:
* Battery Runtime for this model can be increased with the addition of optional external battery packs.
Input Voltage (230V); Input Frequency (50/60 Hz, Auto-Selecting); On-Line Input Voltage Range (166-276 volts); Voltage-Regulated Output
Voltage Range (230V +8%/-15%); On-Battery Output Voltage Range (230V ± 5%); Output Waveform Line Mode (filtered sinewave); Output
Waveform Battery Mode (PWM sine wave); AC Surge Suppression (exceeds IEEE 587 Cat. A & B standards); AC Noise Attenuation
(>40 dB); AC TVSS Protection Modes (H to N, H to G, N to G).
Wire Color-Code Chart
Wire Color
American
European
Wire Reference
American
European
The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change.
Smart INT 2200
2200/1700
27+/11+*
2-4 hrs.
UL, CE
Wire 1
Wire 2
Black
White
Brown
Blue
Wire 1
Wire 2
Line 1
Neutral
Line 1
Line 2 or Neutral
Smart INT 3000
3000/2400
23+/7+*
2-4 hrs.
UL, CE
Wire 3
Green
Black
Green/Yellow
White
Wire 3
AMER
Ground
Green
Ground
Brown
Blue
EURO
Green/
Yellow
7