Error code
Remote control:
E47
Outdoor control PCB
Outdoor inverter
1. Applicable model
2. Error detection method
In order to prevent from
overcurrent of A/F, if the current
exceeds the specifications, it
makes the compressor stopping.
3. Condition of error displayed
• If the output current of A/F
exceeds the specifications,
it makes the compressor
stopping.
4. Presumable cause
• Defective inverter PCB
Note:
LED
Green
Indoor
Keeps flashing
Keeps flashing
Yellow LED
PCB
7-time flashing
5. Troubleshooting
power source
voltage OK?
checked results of
insulation resistance and
resistance between terminals (1) of
compressor motor
Red
Content
Stays off

Inverter PCB A/F module anomaly

1-time flash
Diagnosis
Is the
YES
Is the
OK?
(1) 0.722 or more at 20°C (Model FDC71VNX-W)
YES
110
-
-
'19 • PAC-SM-332
Countermeasure
Check power source.
NO
Replace compressor.
NO
Defective outdoor inverter
PCB ➞ Replace.