Bending the refrigerant piping at the back of the unit needs to be done with the highest care! The piping
consists of copper. When bending the highlighted part more than 1 time the Copper will start cracking due
to a physical process. Cracking can cause leakage refrigerant leakage and is not covered by the warranty.
See picture 2.
Do not bend!
Bend
(Only 1 x)
e.
Feed the condensation hose through the hole in the wall and connect it to the hose which is installed
on the interior unit. See chapter 9.1.
G
TIP
The condensation hose can be more easily attached by pulling the bottom of the interior unit
about 5 cm from the wall and putting something temporarily between it and the wall so that the
gap remains open. See figure 3.
f.
Now click the bottom hooks to of the interior unit to the mounting plate.
g.
Position the exterior unit see chapter 5.2
h.
Connect the quick connector coupling with the coupling on the exterior unit. Then connect the
power cable with the earth wire to the interior and exterior unit. See chapter 8.
i.
Check the air conditioner for any cooler liquid leakage. See chapter 13.
j.
Check that the air conditioner is properly installed.
k.
Connect the plug of the power supply cable to the power supply (models SCJA 4816 must be connec-
ted directly to the power supply without using a plug ) and check that the air conditioner is working
properly. See chapter 11.1.
4.

DETERMINING THE LOCATION OF THE INSIDE AND OUTSIDE UNIT.

4.1 Determining the location of the inside and outside unit.
Do not expose the indoor unit to heat or steam.
Select a place where there are no obstacles in front or around the unit.
Make sure that condensation drainage can be conveniently routed away continuously going down-
wards.
Do not install near a doorway.
Ensure that the space on the left and right of the unit is more than 12cm.
Use a wire detector to detect wires and/or electric cables. to locate studs to prevent unnecessary
damage to the wall.
Bend
(Only 1 x)
Figure 2
4
23