Safety Information
Important safety instructions must be followed for operating and storing the
UDP1306C. To ensure your personal safety, read the following instructions
carefully before operation to ensure that the UDP1306C is in the best working
environment.
Caution
Danger! High Voltage
Ground Terminal
Safety Guidelines
General
Do not block and isolate the air inlet and vent
Avoid physical impact or using the instrument improperly
Do not discharge static electricity onto the instrument
Only professionals should open the instrument
AC Input
AC input voltage: 110V/120V/220V/230V, 50/60Hz
Connect the protective ground wire to the earth to avoid shock hazard.
Fuse Type
Corresponding fuse type for the model:
Model
100V/120V
UDP1306C
T6.3AL/250V(20X5mm)
Make sure to use the correct fuse type before starting up
To prevent fires, only replace with fuses that meet the model and rating
value
Do not connect the power cord before replacing the fuse to avoid electric
shock
Confirm the cause of the blown fuse before replacing the fuse
Power Supply
AC input voltage includes 100V/120V/220V/230V±10%, 50/60Hz. You can
select different input voltages through the "AC SELECTOR" on the rear panel
according to actual needs, please disconnect the power connection before
switching the input voltage
UDP1306C Program Control DC Power
Supply Introduction
The UDP1306C DC power supply has two groups of independent outputs:
the adjustable output of 32V/6A, which has the constant voltage (CV)
and constant current (CC) modes, and the fixed output of 5V/2A with
protection features of short circuit and overvoltage.
UDP1306C Main Features
4-digit voltage and current
high precision display
Overvoltage,overcurrent and
over-temperature protection
Output voltage/current settings
can be viewed
Remote control (output ON/OFF)
Shutdown memory
Keypad lock
Intelligent temperature-controlled fan
USB phone charging interface
RS232 program control
communication
USB device communication
5 sets of data storage
1. Ch1output voltage adjustment knob
2. M1-M5 data storage button
3. CH1 output current adjustment knob
4. Buzzer switch
5. Keypad lock
6. OUTPUT button
7. Channel CV/CC indicator (green-CV, red-CC)
8.Green channel binding post (ground)
9. Black channel binding post (negative)
10. Red channel binding post (positive)
11. Mobile phone charging USB interface (5V/2A)
12.Power switch
13. Output power
14. Current
15. Voltage
16. Product model: UDP1306C
17. Remote control switch
18. USB Device communication interface
220V/230V
19. RS232 communication interface
T3.15AL/250V(20X5mm)
20. Power supply interface
21. Voltage selector
22. Power supply louver
Main Index Parameters
Test conditions: Turn on the device for 30 minutes at
temperature 25℃±5℃
Ch1
Output Voltage
Output Current
Power Supply Regulation
Constant Voltage
Constant Current
Load Regulation
Constant Voltage
Constant Current
Resolution
Voltage
Current
Programming Accuracy
Voltage
Current
Read Back Resolution
Voltage
Current
Ripple and Noise (5Hz-20MHz)
Voltage
Current
Temperature Coefficient
Voltage
Current
USB
Output Voltage
Output Current-limiting Protection
Current Regulation
Load Regulation
Technical Index
0-32V
0-6A
<0.01%+3mV
<0.1%+3mA
<0.01%+5mV
<0.1%+10mA
10mV
1mA
<0.5%+20mV
<0.5%+10mA
10mV
1mA
≤2mVrms
≤3mArms
≤300ppm/℃
≤300ppm/℃
5.0V ±5%
2.0A≤USB≤3A
≤5mV
≤5%

Advertisement

loading

Summary of Contents for UNI-T UDP1306C

  • Page 1 Safety Information Important safety instructions must be followed for operating and storing the UDP1306C. To ensure your personal safety, read the following instructions carefully before operation to ensure that the UDP1306C is in the best working environment. Caution 1. Ch1output voltage adjustment knob Danger! High Voltage 2.
  • Page 2 10. Remote Interface Control voltage threshold value. UDP1306C power supply supports the communication between RS232 interface Long press VOLTAGE knob, OVP symbol is lighten, the voltage output value and the computer base on SCPI communication instruction, please refer to returns to zero, OVP is enable (if output is on).