INSTALLATION

8
INSTALLATION

Select the best Location

- There should not be any heat or steam near
the unit.
- Select a place where there are no obstacles
around of the unit.
- Make sure that condensation drainage can
be conveniently routed away.
- Do not install near a doorway.
- Ensure that the interval between a wall and
the left (or right) of the unit is more than 100
mm. The unit should be installed as high as
possible on the wall, allowing a minimum of
200 mm from ceiling.
- Use a metal detector to locate studs to pre-
vent unnecessary damage to the wall.
More than
100
More than 2300
* The feature can be changed according to
type of model.
!
CAUTION
Install the indoor unit on the wall where
the height from the floor is more than
2300 mm.

Fixing Installation Plate

The wall you select should be strong and solid
enough to prevent vibration
1
Mount the installation plate on the wall
with type "A" screws. If mounting the unit
on a concrete wall, use anchor bolts.
- Mount the installation plate horizontally
by aligning the centerline using Horizontal
meter .
More than 200
More than
100
(Unit : mm)
Installation Plate
Chassis
Hook
2
Measure the wall and mark the centerline.
It is also important to use caution concern-
ing the location of the installation plate.
Routing of the wiring to power outlets is
through the walls typically. Drilling the hole
through the wall for piping connections
must be done safely.
SB chassis
Place a level on raised tab
Unit Outline
442
Ø65
Installation Plate
133
175
SC chassis
Place a level on raised tab
Unit Outline
460
Installation Plate
Installation Plate
Installation Plate
Ø65
Ø65
Ø65
Measuring Tape
69
105
Measuring Tape
Hanger
Type "A" Screws
442
Ø65
Ø65
Ø65
95
217
(Unit : mm)
570
Ø65
56
207
(Unit : mm)