Code Input Example - Mitsubishi Electric 700 Series Instruction Manual

Plug-in option
Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

CONNECTION DIAGRAM AND TERMINAL
4.4

Code Input Example

The following explains examples of terminal status and input value at BCD code input and binary input.
Example: when the input value is 6325
BCD Code Input
Terminal
Terminal input
Digit
name
X0
X1
1
X2
X3
X4
X5
10
X6
X7
X8
X9
100
X10
X11
X12
X13
1000
X14
X15
CAUTION
• For the BCD code input, the input value of each digit is from 0 to 9. When the value greater than 9 is input, it
is made invalid and the last value is retained.
24
Input
status
value
ON
OFF
5
ON
OFF
OFF
ON
2
OFF
OFF
ON
ON
3
OFF
OFF
OFF
ON
6
ON
OFF
Example: when the input value is AB65
Binary Input
Terminal
Terminal input
name
status
X0
ON
X1
OFF
X2
ON
X3
OFF
X4
OFF
X5
ON
X6
ON
X7
OFF
X8
ON
X9
ON
X10
OFF
X11
ON
X12
OFF
X13
ON
X14
OFF
X15
ON
H
Input
Input value
value
(hexadecimal)
(decimal)
5
6
43877
B
A