SECTION 5—PERFORMANCE ADJUSTMENTS

NX-LP

NOTE: For this procedure, refer to FIGURE 5.3.
The Performance Adjust Menu for NX-LP consists of the following:
➜ FORWARD SPD
TURNING SPD
ACCELERATION - FWD
ACCELERATION - REV
REVERSE SPEED

Making Performance Adjustments

DO NOT mismatch a program with the wheelchair type (i.e. selecting a rear wheel
drive program for a center wheel drive wheelchair or vice versa). Adverse joystick
control of the wheelchair will occur, possibly resulting in serious bodily injury.
NOTE: If unsure if correct program is selected, perform the instructions outlined in Programs on
page 31 before making performance adjustments.
The selection arrow points to PERFORMANCE ADJUST. To select this activity press the
SELECT key.
➜ PERFORMANCE ADJUST
PROGRAMS
OTHER
The display screen will change to show the first four performance functions and the
programmed value for the functions. The selection arrow points to the first function -
Forward Speed. Pressing the
Continue pressing the
in NX, NX-50, NX-75, NX w/ACC, and NX-B Controller on page 24 or NX-LP Controller
on page 26.
➜ FORWARD SPEED
TURNING SPEED
ACCELERATION - FWD
ACCELERATION - REV
MK
™NX™Electronics
5
FIGURE 5.3 Performance Adjust Menu - NX-LP
WARNING
or
key will move the selection arrow up or down.
or
key to cycle through all the options listed in the flowchart
22
Remote
Programmer
LCD Display
Part No 1110532