Screen Display 1) Temperature display 6) Relative mode 2) Low BATT display 7) Data HOLD mode 3) K type of T/C 8) Degrees °C /°F thermocouple 9) T1/T2 thermocouple 4) Auto power off or T1-T2 differential 5) MAX/MIN reading...
• Repeated sharp flexing can break the thermocouple leads. To prolong lead life, avoid sharp bends in the leads, especially near the connector. UNPACKING AND INSPECTION Your shipping carton should include: TMD-50 meter Manual K type Thermocouple AAA Batteries Plain white box...
INTRODUCTION There are 2 sets of sockets for thermocouple plugs at the top of instrument marked with T1 and T2. Features • Highly accurate dual input thermometer with 0.1% basic accuracy. • Dual input T1, T2, T1-T2. • Thermocouple offset adjust. •...
key once more to cancel the Back-Light function. Back-Light on lighter Back-Light off “ADJ” Button: Adjust thermocouple offset 1. Insert the bead wire into a known temperature (T) until the display equal to known temperature (T). exp: ice point at 0°C boiling water at 100°C (Press “ADJ”...
“MAX/MIN” Button Press “MAX/MIN” key to enter the MIN MAX recording mode. (Displays the Maximum reading, Minimum reading, “MAX-MIN”, “AVG” reading stored in record mode). Press “MAX/MIN” key to cycle through the MAX, MIN, MAX-MIN, “AVG” readings. In this mode, press “HOLD”...
Page 13
Accuracy Accuracy is specified for operating temperatures over the range of 18°C to 28°C (64°F to 82°F), for 1 year, not including thermocouple error. ±(0.1%rdg+1°C) on -60°C to 1372°C ±(0.1%rdg+2°C) on -60°C to -200°C ±(0.1%rdg+2°F) on -76°F to 1999°F ±(0.1%rdg+4°F) on -76°F to -328°F Environmental Ambient 0°C to 50°C (32°F to 122°F) <80% R.H.
� - EMC: Conforms to EN61326-1. This product complies with requirements of the following European Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit.
Page 15
1. Power is supplied by 4pcs 1.5V (SIZE AAA) UM-4 R03. 2. The “ ” appears on the LCD display when replacement is needed. To replace battery remove screw from back of meter and lift off the battery cover. 3. Remove the batteries from the battery compartment and replace them with new ones.