Controls and Connectors

AXT631
606-814 MHz
Antenna Distribution
Ampli er
4
5
AXT631
① LCD Display
Displays menu and settings.
② Navigation Buttons
• Arrows: Scroll menus and change settings
• SET: Enables menu edits and saves changes
③ Power Switch
Powers the unit on or off
④ AC Power Primary Switch
AC Main Power Switch
⑤ AC Power In
IEC Connector, 100-240 V AC
⑥ AC Power Cascade
Use the IEC extension cables to connect up to 5 devices to a single AC
power source.
⑦ Network Speed LED (amber):
• Off = 10 Mbps
• On = 100 Mbps
⑧ Ethernet Ports (2)
PoE Class 1 enabled. Connect to an Ethernet network to enable remote
control and monitoring
1
2
SET
6
7
9
4B
PoE Class 1
8
RF outputs
3B
2B
1B
4A
3A
10
⑨ Network status LED (green)
• Off = no network link
• On = network link active
• Flashing = network link active, flash rate corresponds to traffic
volume
⑩ RF Output Connectors, Channel B
Distributes RF signal for Channel B
⑪ RF Output Connectors, Channel A
Distributes RF signal for Channel A
⑫ Antenna IN Ports, Channels A and B
Antenna inputs are DC biased for use with active antennas or in-line
amplifiers.
⑬ RF Cascade Ports, Channels A and B
Passes the wideband RF signal from one device to the next, allowing up
to 5 devices to share a single pair of antennas.
⑭ Antenna Input Status LED
• Green = DC power on
• Off = DC power off
• Red = Antenna fault or over-current condition
2
3
power
12
RF outputs
2A
1A
14
B
11
13
antenna
in
A