4 Installation and Startup

4.2 Startup (JOG from drive side)

Startup (JOG from drive side)
4.2
Table 4-1
Nr.
1. Set drive parameter p29108 to be 1.
2. Switch to JOG menu with drive BOP operation.
3. Press
or
4.3

Startup (PROFINET communication)

Table 4-2
Nr.
1. Set drive parameter p922 to be 1.
2. Make device & network configurations in the
TIA Portal:
 Device name
 IP address
 Telegram
3. Go online to test the PROFINET
communication.
4. Download configurations into controller and
device if the communication works.
Speed control with SINAMICS V90 and S7-300 via Profinet
Entry-ID: 109743898,
V1.0,
Action
button to run the motor.
Action
07/2016
Remarks
JOG function is enabled when p29108=1
Remarks
Select standard telegram 1
As shown in section 3.2.3
16