5.6

Ethernet Interface X71

1070 072 263-101 (01.08) GB
The Ethernet interface on the frontside serves for external connection of the
ZS550. Ethernet and Internet protocols are the basis for communication. On
an Ethernet basis, the UDP/IP standard protocol is used in order to send
Bosch BÜP commands. The interface can be addressed directly from the
PLC program. It can be operated with a transfer rate of up to 100 Mbits/s.
A patch cable connects the ZS550 to a network connection. The network is
connected via an RJ45 socket.
1
3
4
7
Pin
1
2
3
4
5
6
7
8
Assignment
TX_D1+
TX_D1–
RX–D2+
BI_D3+
BI_D3–
RX_D2–
BI_D4+
BI_D4–
ZS550