Superior VCI3032ZMN Installation And Operation Instructions Manual page 13

Unvented (vent-free) gas fireplace insert
Table of Contents

Advertisement

Equipment
Shutoff Valve
Figure 17 - Equipment Shutoff Valve
Manual Gas Valve
f i r e - p a r t s . c o m
Figure 18 - Checking Gas Joints (Natural Gas)
Equipment Shutoff Valve
Manual Gas Valve
Figure 19 - Checking Gas Joints (Propane/LP Gas)
PRESSURE TESTING FIREPLACE INSERT GAS CONNECTIONS
1. Open equipment shutoff valve (see Figure 17).
2. Open main gas valve located on or near gas meter for natural gas
or open propane/LP supply tank valve.
3. Make sure control knob of fi replace insert is in the OFF position.
4. Check all joints from gas meter to equipment shutoff valve for
natural gas (see Figure 18) or propane/LP supply to equipment
shutoff valve for propane/LP (see Figure 19). Apply a noncor-
rosive leak detection fl uid to all joints. Bubbles forming show a
leak.
5. Correct all leaks at once.
6. Light fi replace insert (see Operation, Page 16). Check all other
internal joints for leaks.
7. Turn off fi replace insert (see To Turn Off Gas to Appliance, Page
17).
127119-01C
INSTALLATION Continued
FIREPLACE INSERT INSTALLATION INTO MASONRY FIREPLACE
Open
NOTE: These heaters are designed to be installed into an existing
masonry fi replace (built to UBC 37 or ULC S628 standards) or fac-
tory built solid fuel, wood-burning fi replace (listed to UL 127 or ULC
S610) only.
Closed
If using a mantel above the fi replace, you must follow the clearances
shown in Figure 12, Page 10. Follow instructions below to install
fi replace insert in this manner.
1. Use dimensions shown in Figure 20 for masonry fi replace open-
2. Install and properly ground GA3555, three-prong 120 volt electrical
Equipment
Shutoff Valve
3. Install gas piping to fi replace location. This installation includes
Gas Meter
4. Carefully set fi replace insert in front of masonry fi replace with
5. Attach fl exible gas line to gas supply. See Connecting Fireplace
6. Plug electrical cord into electrical outlet installed in step 2.
7. Carefully place fi replace insert into masonry fi replace.
8. Check all gas connections for leaks. See Checking Gas Connec-
Propane/
LP Supply
9. Install trim after fi nal fi nishing and/or painting of wall (see Figure
Tank
ASSEMBLING AND ATTACHING TRIM
SuperiorFireplaces.us.com
ing.
outlet, in fi replace insert. Follow instructions included in kit (see
Accessories, Page 28).
an approved fl exible gas line (if allowed by local codes) after
equipment shutoff valve. Flexible gas line must be the last item
installed on gas piping. See Installing Gas Piping to Fireplace
Location, Page 11.
back of insert inside opening.
Insert to Gas Supply, Page 12.
tions, Page 12.
22, Page 14).
Insert
Height
25
Front Width
34
Depth
16
1
26
/
"
4
Figure 20 - Rough Opening for Installing in Masonry Fireplace
Minimum Fireplace
Opening
9
/
"
26-1/4"
16
5
/
"
35"
16
11
/
"
17-1/4"
16
1
17
/
"
4
35"
13