WMK 160 • Installation Guide (Continued)
The key components (base plate, cover, and PVS switcher mounting
plate) of the WMK 160 are shown in figure 1 at right. Included in the kit
are the following:
(4) ¼-20 x 2" pan head bolts, (4) ¼" KapToggle
(2) #14 x 1¾" self tapping metal/wood screws, (4) cover screws.
Not shown but included are (3) 4-40 x ¼" screws, (2) tie wraps
(15"), (8) 4-40 x 3/16" screws (used to attach other Extron devices).

Installation

NOTE:
Refer to local building standards and codes to verify that
the installation will meet the regulatory requirements. Observe all
local and national building and safety codes, UL requirements,
and ADA accessibility guidelines.
Before installation identify the type of wall (masonry or non-masonry)
and the location where the WMK 160 will be installed. This determines
the installation approach and type of fasteners needed to secure the
plate to the wall.
Step 1.
Mount the Base Plate
Follow the steps within 1A or 1B, as applicable.
NOTE:
The base plate can be installed over an existing electrical
outlet (see figure 2 at right).
1A. To mount the WMK 160 onto masonry walls:
i.
Hold the base against the wall, level it, and mark the
positions of four slotted mounting holes (indicated by
+ marks in figure 2 at right). Set the plate aside.
ii.
Using a masonry drill bit, drill 1¾ inch (4.4 cm) deep
pilot holes at the marked locations.
iii.
Screw in ¼ x 1¾ inch masonry screws (not supplied)
until a gap of about 3/8 inch (9 mm) remains between
the wall and the screw heads.
iv.
Align the slotted mounting holes of the base plate
over the installed screws, then slide the plate
down so the screws fit into the slots (see figure at
immediate right).
v.
Verify level and position and tighten all the screws to secure the plate flush to the wall.
Proceed to step 2.
1B. To mount the WMK 160 onto a non-masonry wall:
i.
At the desired site, locate and mark the wall studs.
NOTES:
For ideal installation secure the base plate to at least
one wall stud (see
can be used for holes not aligned with studs.
Always use the widest spacing of screws and
KapToggles.
The base plate can be installed over an existing
electrical outlet (see figure 2 above).
ii.
Hold and level the base plate against the wall and mark
the positions of the slotted mounting holes that are on
the stud lines (see
applicable, mark the mounting holes on the wall for
drywall toggles.
2
assemblies,
®
figure
3 at right). Drywall KapToggles
figure
3 indicated by + marks). Where
(1) WMK 160 Base Plate
(1) WMK
K 160 Base Plat
(1) WMK 160 Cover
Figure 1.
WMK 160 parts
Mounting
WMK 160
Holes
Base Plate
Figure 2.
Masonry wall mounting
Mounting
Holes
WMK 160
Base Plate
Wall Studs
Figure 3.
Non-masonry wall mounting
(4) 1/4"
(4) 1/4" KapToggle
®
Assemblies
Asse
(4) 1/4-20 x 2"
(4)
Pan Head Bolts
(2) #14 x
(2) #14 x 1 3/4"
Self-
Self-tapping
Meta
Metal/Wood Screws
(4) Cove
(4) Cover Screws
t
e
e
e
(1) Pol
(1) PoleVault Switcher
Mou
Mounting Plate
Marker for
Pilot Hole
Level
Cutout for
Electical
Outlet
Cutout for
Signal Cable
Access
Marker for
Pilot Hole
Level
Cutout for
Electrical
Outlet
Cutout for
Signal Cable
Access