EQUIPMENT CONNECTION / ADJUSTMENT PROCEDURE
Input
Input
Connection Point
Regulated
power
supply
Pattern
generator
Input
TP101
Pattern
TP101
generator
VCC2 Voltage Setting
Regulated
power
supply
Input
DC Jack
5.0 ± 0.05 V
Input
Adjust
Signal
VR100
VBL Voltage Setting
QV-10
Input
DC Jack
5.0 ± 0.05 V
VR101
Vcom Adjustment
QV-10
Oscilloscope
Set
Output
TP410
VR303
Color bar
38.9 MHz
VR302
QV-10
Set
Output
TP107
Output
Output
Connection
Point
Adjust for 4.50 ± 0.02 V
Voltmeter
TP107
reading on voltmeter.
Voltmeter
Set
Output
TP110
Voltmeter
TP110
Adjust VR303 so that square-
wave to read 6.0 ± 0.1 V.
Adjust VR302 so that high
Oscilloscope
TP410
level of the square-wave is at
0.0 ± 0.25 V.
— 14 —
Voltmeter
Result
Adjust for 5.0 ± 0.05 V
reading on voltmeter.
0 ± 0.25 [V]
6.0 ± 0.1 [V]