NOTICE
Appliances have been tested
NOT
or verified by Beckett but
the appliance manufacturer, unless noted. These
settings are not intended to supersede the appliance
manufacturer's published specifications. Always follow
the appliance manufacturer's published instructions
and recommendations.
NOTICE
The recommended air settings are intended for use only as a starting point for burner adjustments.
The settings cannot make provisions for all installation possibilities. It is important that the burner is adjusted to the installation
requirements using properly calibrated flue gas analysis instruments.
Buderus
Beckett
Appliance
Required
Appliance
Input BTU
Input BTU
G115-3
96,000
90,000
G115-4
126,000
130,000
G115-5
154,000
145,000
Beckett
Appliance
Required
Appliance
Input BTU
Input BTU
*
G215-3
154,000
145,000
*
G215-4
196,000
190,000
* Heat Exchanger Baffles Must Be Removed to Achieve Appropriate Flue Temperature Above 325°F.
V8 Series
Beckett
Appliance
Required
Appliance
Input BTU
Input BTU
V83
105,000
110,000
V83
147,000
145,000
V84
147,000
160,000
V84
189,000
175,000
V85
189,000
190,000
V85
231,000
220,000
MPO Series
Beckett
Appliance
Required
Appliance
Input BTU
Input BTU
MPO115
115,000
110,000
*
MPO147
147,000
145,000
*
MPO189
189,000
190,000
* Heat Exchanger Baffles Must Be Removed to Achieve Appropriate Flue Temperature Above 325°F.
Beckett Tested or Verified Appliance List
tested or endorsed by
Burner
Air Tube
Chassis
Combination
Part #
Part #
Head
CG4001
CG4BUF3
F3G
CG4001
CG4BUF3
F3G
CG4001
CG4BUF4
F4G
Burner
Air Tube
Chassis
Combination
Part #
Part #
Head
CG4001
CG4BUF4
F4G
CG4001
CG4BUF6
F6G
Burner
Air Tube
Chassis
Combination
Part #
Part #
Head
CG4001
CG4MUF3
F3G
CG4001
CG4MUF4
F4G
CG4001
CG4MUF4
F4G
CG4001
CG4MUF4
F4G
CG4001
CG4MUF6
F6G
CG4001
CG4MUF6
F6G
Burner
Air Tube
Chassis
Combination
Part #
Part #
Head
CG4001
F3G
CG4BMPOF3
CG4001
CG4BMPOF4
F4G
CG4001
CG4BMPOF4
F4G
WARNING
Professional Service Required
Failure to follow these recommended settings could lead to
equipment malfunction and result in asphyxiation, explosion or fire.
. Please read the CG4 manual and follow all instructions completely.
. The installation must comply with all local codes and ordinances
having jurisdiction and the latest edition of National Fuel Gas Code
ANSI Z223.1 (NFPA 54) and CAN1-B149.1 in Canada.
NG
LP
Orifice
Orifice
Insertion
Size
Size
5.25"
0.234
0.177
5.25"
0.364
0.234
5.25"
0.316
0.234
NG
LP
Orifice
Orifice
Insertion
Size
Size
5.25"
0.316
0.234
5.25"
0.354
0.256
NG
LP
Orifice
Orifice
Insertion
Size
Size
1.75"
0.277
0.206
1.75"
0.316
0.234
1.75"
0.348
0.246
1.75"
0.406
0.261
1.75"
0.354
0.256
1.75"
0.422
0.281
NG
LP
Orifice
Orifice
Insertion
Size
Size
0.277
0.266
2.00"
2.00"
0.316
0.234
2.00"
None
0.281
5
Air Settings
Shutter /Band
Air Band / Slot
Baffle
(see notices)
Number
5880
S-7 / B-0
NONE
S-5 / B-0
4 - Slot
5880
S-10 / B-1
4 - Slot
Air Settings
Shutter /Band
Air Band / Slot
Baffle
(see notices)
Number
NONE
S-5 / B-0
4 - Slot
NONE
S-8 / B-0
4 - Slot
Air Settings
Shutter /Band
Air Band / Slot
Baffle
(see notices)
Number
5880
S-7 / B-0
5880
S-10 / B-0
4 - Slot
5880
S-10 / B-0
4 - Slot
None
S-6 / B-0
4 - Slot
None
S-8 / B-0
4 - Slot
None
S-9 / B-0
4 - Slot
Air Settings
Shutter /Band
Air Band / Slot
Baffle
(see notices)
Number
5880
S-8 / B-0
4 - Slot
5880
S-6 / B-0
4 - Slot
None
S-10 / B-1
4 - Slot
Blank
Blank