Siemens SINUMERIK 840Di Diagnostic Manual page 206

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
14092
Channel %1 block %2 axis %3 is wrong axis type
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
One of the following programming errors has occurred:
1. The keyword WAITP(x) "Wait with block change until the specified positioning axis has reached its
end point" has been used for an axis that is not a positioning axis.
2. G74 "Reference point approach from the program" has been programmed for a spindle. (Only axis
addresses are permitted).
3. The keyword POS/POSA has been used for a spindle. (The keywords SPOS and SPOSA must be
programmed for the spindle positions).
4. If the alarm occurs with the rigid tapping function (G331),
the following causes are conceivable:
- The master spindle is not in position-controlled mode.
- Incorrect master spindle
- Master spindle without encoder
5. An axis name was programmed which no longer exists (e.g. when using axial variables as an
index). Or it was programmed as index NO_AXIS.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Correct the part program according to which of the above errors is involved.
- Program SPOS.
- Set the correct master spindle with SETMS.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14093
Channel %1 block %2 path interval <= 0 with polynominal interpolation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In the polynomial interpolation POLY, a negative value or 0 has been programmed under the keyword
for the polynomial length PL=...
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM
CORRECT. The correction pointer positions on the incorrect block.
Correct the value given in PL = ...
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
2-206
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition