Hide thumbs Also See for CB202:

Advertisement

Quick Links

Chamberlain GmbH, Alfred-Nobel-Strasse 4, 66793 Saarwellingen Germany +++ www.liftmaster.eu +++ info@liftmaster.eu
de
Anleitungen
Instructions
fr
Instructions
en
Návody
cs
Instrucciones
es
Instruktioner
sv
Útmutatók
hu
Upute
hr
Istruzioni
it
Instruktie
nl
Obrázky
sk
Instrukcja
pl
AT/BA/BE/BG/CH/CY/CZ/DE/DK/ES/
FR/GB/GR/HR/HU/IE/IS/IT/LU/MT/NL
NO/PL/PT/RO/RU/SE/SI/SK/TR/YU
CB202
CB202
CB202
CB202
CB202
CB202
CB202
CB202
CB202
CB202
CB202
CB202

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain CB202

  • Page 1 Anleitungen CB202 Instructions CB202 Instructions CB202 Návody CB202 Instrucciones CB202 Instruktioner CB202 Útmutatók CB202 Upute CB202 Istruzioni CB202 Instruktie CB202 Obrázky CB202 Instrukcja CB202 AT/BA/BE/BG/CH/CY/CZ/DE/DK/ES/ FR/GB/GR/HR/HU/IE/IS/IT/LU/MT/NL NO/PL/PT/RO/RU/SE/SI/SK/TR/YU Chamberlain GmbH, Alfred-Nobel-Strasse 4, 66793 Saarwellingen Germany +++ www.liftmaster.eu +++ info@liftmaster.eu...
  • Page 2: Table Of Contents

    TOPIC PAGE SAFETY RULES ..................1 TYPICAL CONFIGURATION OF A UNIT .
  • Page 3: Safety Rules

    WARNING / ATTENTION IMPORTANT FITTING AND OPERATING INSTRUCTIONS PLEASE START BY READING THESE IMPORTANT SAFETY RULES This safety alert symbol means "Caution" - failure to comply with such an instruction involves risk of personal injury or damage to property. Please read these warnings carefully. This gate drive mechanism is designed and tested to offer appropriately safe service provided it is installed and operated in strict accordance with the following safety rules.
  • Page 4: Typical Configuration Of A Unit

    2.5m. INSTALLATION OF CONTROL BOARD The CB202 control board was designed for installation in a special covering under the housing of the sliding gate drive. The installation of the electrical controller is allowed only after the completion of the mechanical installation.
  • Page 5: Wiring Of Control Board

    WIRING OF CONTROL BOARD See page 5 for Description of The cables for the power supply and the connected equipment are routed from below into the sliding door operator through the rubber the terminals! seal at the bottom of the control covering. The controller is to be mounted with the terminal strips down as shown in the picture.
  • Page 6: Wiring Diagramm

    WIRING DIAGRAM Radio 433MHz 230V~ +/- 10% 50Hz 8.2 k Ω PHO1 close/schliessen/fermer/sluiten Model CM475 PHO2 close/schliessen/fermer/sluiten close/schliessen/fermer/sluiten open/öffnen/ouvrir/open TECHNICAL DATA OF CONTROL BOARD The motor control unit is a highly modern electronic unit controlled by Voltage: 230 V~ / 50 Hz ±10% a microprocessor.
  • Page 7: Description Of Terminals

    DESCRIPTION OF TERMINALS DESCRIPTION OF LEDS (LIGHT EMITTING DIODE) Description Function DESCRIPTION COLOUR STATUS 120 -230 VAC STOP / 8.2 kOhms green Stop Switch 50 - 60 Hz ON: Stop Active POWER SUPPLY connector OFF: OK (Requires wire bridge if no TRANSF IN 230 V to transformer switch is connected)
  • Page 8: Backup Battery

    ACCESSORIES (also refer to wiring diagram) BACKUP BATTERY (OPTIONAL) MODEL: CM475 (24V/AC) The terminals serve to reload an externally installed storage battery (Terminal: 30 VDC). In case of power failure the battery provides power to the drive. A fully charged storage battery may provide power for more than 24 hours. Storage batteries are subject to deterioration and lose capacity.
  • Page 9: Photocells

    PHOTOCELLS (OPTIONAL) MODEL: 771E / 772E The photocells are for safeguarding the gate and must be used. The fitting location depends on the gate’s design. EN12453 specifies that a pair of photocells must be installed outside at a height of 200 mm and activated to “Close”. The photocells consist of a transmitter and a receiver and must be opposite each other.
  • Page 10: Loop Detector

    LOOP DETECTOR (OPTIONAL) Jumper OPEN/PED must be plugged Loop detectors react to metal and the most common use is for cars or trucks but not for bikes or pedestrians. Exit loop / Gate Opening Loop An exit loop is behind the gate and opens the gate when closed, keeps it open or re-opens the gate.
  • Page 11: Initial Operation / Basic Setting

    INITIAL OPERATION / BASIC SETTING Proceed step by step. When in doubt, start again at the beginning. Take sufficient time to make these settings. 1. Are all components required for operation connected? Motor, photocells, safety safety edge, stop switch. 2. Limit switches are fixed to the rack? 3.
  • Page 12 PROGRAMMIING THE TRAVEL DISTANCE AND OPERATOR FORCE 1. Gate is closed, gate position is “Close Limit”. LED "CLOSE LIM" glows. 2. Press the button P1 until the door starts to open. (LED "LEARN" glows) The automatic programme starts (slow speed). 3.
  • Page 13: Timer To Close (Auto-Close)

    COMPLETION OF INSTALLATION / PROGRAMMING Once the travel distances are programmed, the remote controls can be programmed as well. (Refer to “Radio and Radio Programming”) 1. You can now let the gate run 2 complete cycles by pressing a key on the remote or a connected switch and observe the process.
  • Page 14: Diagnosis Led

    DIAGNOSIS LED The LED diagnostics always shows the latest upcoming issue. If several issues occur the LED diagnostics does not show them. Example: The gates’ guiding rail is soiled and the drive performs a safety reversal due to too high force. After that the photocell beam got interrupted.
  • Page 15: Faqs

    An appropriate aerial with installation kit can be obtained from Chamberlain as an accessory. Not recommended! Change gate! The gate can move in an uncontrolled (dangerous) manner if The gate must follow a slope.

Table of Contents