Flame Appearance - Lennox SHGL-18VN-R Installation Instructions And Homeowner's Manual

18" & 24" dual-listed gas log sets
Table of Contents

Advertisement

The pressure regulator on manual models is
preset and locked to avoid tampering. If the
pressure is not as specified in the Technical
Details Chart on page 10, replace the regulator
with P/N 110353 for natural gas and P/N
120341 for propane (L.P.G.) heaters.
Replace the test point plug after pressure
measurement ensuring no gas leaks.
Step 4. Placing the Logs
WARNING: DO NOT ADD EXTRA LOGS OR
ORNAMENTS SUCH AS PINE CONES, VER-
MICULITE OR ROCK WOOL. USING THESE
ADDED ITEMS CAN CAUSE SOOTING.
WARNING: DO NOT PLACE ANY LAVA
ROCK ON LOGS OR BURNERS. THIS MAY
CAUSE SOOTING. ONLY PLACE LAVA
ROCK ON FLOOR OF FIREPLACE.
The heater has a unitized base, a front log and
a top twig. It is important to follow the
instructions to place the logs properly over the
burner assembly.
1. Place the front log as shown in Figure 9 (A) .
Position the front log so it fits between the
burner and the front grate bars, resting com-
pletely on the grate base.
2. Place the unitized log set over the burner
assembly as shown in Figure 9 (B) . Be sure
the unitized log set is against the sides of the
burner and is resting down completely over
the grate.
3. When placing the unitized log set over
the burner assembly and resting it against
the sides of the burner, make sure the bot-
tom of the log set sits down completely over
the grate as shown in Figure 9 (C) .
4. Place and lock the top twig over the twig
pins as shown in Figure 9 (D) .
5. For an optimum flame, be sure that the
unitized log set rests against the burner at the
two places shown in Figure 9 (E) .
Grate Base
A
Grate Bar
Front Log
B
Twig Pins
Unitized Log Set Must
C
Lay Flat On Grate Base
D
Top Twig
E
Unitized Log Set Must Be Placed Against Burner Bracket
At These Two Places
Figure 9
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
Manual Log Set
Unitized Log Set
Millivolt Log Set
Figure 10
WARNING: FAILURE TO POSITION THE
PARTS IN ACCORDANCE WITH FIGURE
10 OR FAILURE TO USE ONLY PARTS
SPECIFICALLY APPROVED WITH THIS AP-
PLIANCE MAY RESULT IN PROPERTY
DAMAGE OR PERSONAL INJURY.
Periodically check the positioning of all logs.

Flame Appearance

REFER TO THE OPERATING INSTRUCTIONS
LOCATED AT THE BACK OF THIS MANUAL
BEFORE LIGHTING THE APPLIANCE TO OB-
SERVE THE FLAMES.
Flames from the pilot burner should be visu-
ally checked as soon as the appliance is in-
stalled. In addition a periodic visual check of
the flames should be made. The pilot flame
should always be present when the appliance
is in operation ( Figure 11 ).
WARNING: NO ADJUSTMENTS ARE TO
BE MADE TO THE ODS PILOT SYSTEM.
TAMPERING WITH THIS SYSTEM CAN
BE EXTREMELY HAZARDOUS.
7

Advertisement

Table of Contents
loading

Table of Contents