Mitsubishi Electric FR-A8AC Instruction Manual page 13

Plug-in option
Table of Contents

Advertisement

(2) Loosen the terminal screw and insert the cable into the terminal.
Terminal
Tightening torque
screw size
M2
0.22N.m to 0.25N.m
NOTE
• Undertightening can cause cable disconnection or malfunction. Overtightening can cause a short circuit or malfunction
due to damage to the screw or unit.
• Use a screwdriver with a diameter of 1.6 mm or less. To avoid contact with the relay, put the screwdriver upright
relative to the terminal screw surface. Otherwise, the relay or the terminal block may be damaged by the screwdriver
because of the limited space between the terminal block and the relay.
Connector
Avoid contact with
the relay.
Cable size
2
2
0.3mm
to 0.75mm
Terminal block
Keep the screwdriver upright relative to
the terminal screw surface while rotating the
screwdriver.
Relay
1.6 mm or less
Screwdriver
Small
flat-blade screwdriver
(Tip thickness: 0.4mm/tip width: 2.5mm )
INSTALLATION AND WIRING