Loosen the clamping bolt.
Turn the eccentric plate anti-clockwise with a
screwdriver or a torx driver. This tightens the drive belt
by pushing the bar forwards.
Tighten the nuts.
Screw the bolt tight. Hold still the eccentric plate so
that it doesn't move along when you tighten the
screws.
NOTICE! A new drive belt shall be tightened once after
30-60 minutes operation.
Replacing the drive belt
Release the belt tension.
Remove the blades.
20 - English
MAINTENANCE
Remove the belt cover by loosening the nuts, the
clamping bolt and the eccentric cam.
Loosen water hose.
Loosen the drive gear. Use a spanner as a
counterhold. (The combination spanner or bearing
tool can be used as a counterhold.)
Remove the cutting arm by pulling it straight out from
the machine.