Supplementary system components

6.8 Terminal Module TM54F

6.8
Terminal Module TM54F
Properties of the TM54F
The TM54F terminal module is a terminal expansion module for snapping on to a DIN EN
60715 mounting rail. The TM54F offers safe digital inputs and outputs for control of Safety
Integrated functions of SINAMICS.
Exactly one TM54F can be assigned to each drive control (SINAMICS Integrated of a
D4x5-2, CX32-2, CU320-2, etc.). Connection is via DRIVE-CLiQ. Each drive control must
have its own dedicated TM54F.
TM54 is equipped with the following terminals:
Table 6- 38
Type
Fail-safe digital outputs (F-DO)
Fail-safe digital inputs (F-DI)
Sensor
supported
Sensor
Digital inputs for testing the F-DO during test stop 4
Sensors: Fail-safe devices for commanding and detecting, such as emergency stop
1)
pushbuttons and safety locks as well as position switches and light arrays / light curtains.
Dynamic response: The sensor power supply is switched on and off during test stop for
2)
testing the sensors, the cable routing, and the evaluation electronics of TM54F.
The TM54F has four fail-safe digital outputs and ten fail-safe digital inputs. A fail-safe digital
output consists of a P/M-switching output as well as a digital input for reading back the
switching state. A fail-safe digital input is made up of two digital inputs.
The 50 mm clearances above and below the component must be observed.
Additional references
You will find detailed information about the TM54F terminal module in the following sources:
130
Interface overview
power supplies, dynamic response
1)
2)
power supplies, no dynamic response
1)
CAUTION
SINAMICS S120 Control Units and Additional System Components
SINAMICS S120 Safety Integrated
Quantity
4
10
2
1
Function Manual