Typical Installation; Warning Signs - Graco A Series Instructions-Parts List Manual

Air spray gun
Hide thumbs Also See for A Series:
Table of Contents

Advertisement

Connection for 75 KV Power Supply
Power Supply Must Be Interlocked
With Spray Booth Exhaust Fan.
KEY
A
Air Supply Line
B
Air & Water Separator
C
Ball Valve
D
Air Line Lubricator
E
Air Regulator (bleed–type)
F
Pump
G
Fluid Filter
The Typical Installation shown above is only a guide for
selecting and installing electrostatic air spray systems. It
is not an actual system design. The particular type and
size system for your operation must be custom designed
for your needs. For assistance in designing a system,
contact your Graco representative.

Warning Signs

Mount warning signs in the spray area where they can
easily be seen and read by all operators. See the AC–
CESSORIES section on page 25.

TYPICAL INSTALLATION

NON–HAZARDOUS AREA
H
Remote Switch and Lights Wiring
J
ON–OFF (D.P.–D.T.) Switch
K
High Voltage Power Supply
(located outside the spray/hazardous area)
L
Remote Switch & Lights
M
Air Filter (5 micron)
N
High Voltage Cable
WARNING
Installing and servicing this equipment requires ac-
cess to parts which may cause electric shock or
other serious bodily injury if the work is not per-
formed properly. Do not install or service this equip-
ment unless you are trained and qualified.
Be sure your installation complies with National,
State and Local codes for the installation of electri-
cal apparatus in a Class 1, Group D, Divisions 1 and
2 Hazardous Location.
WARNING
SIGN
HAZARDOUS AREA
O
Fluid Regulator
P
Fluid Line
Q
Electrostatic Gun
R
Atomizing Air Line
S
Air Supply Shutoff Valve
(bleed–type)
T
Fluid Drain Valve