Amprobe ACD-14 PLUS User Manual
Hide thumbs Also See for ACD-14 PLUS:

Advertisement

Quick Links

Users Manual
Visit us at www.TestEquipmentDepot.com
ACD-14 PLUS
ACD-14 TRMS-PLUS
Clamp-on Multimeter
With Dual Display
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431

Advertisement

Table of Contents
loading

Summary of Contents for Amprobe ACD-14 PLUS

  • Page 1 ACD-14 PLUS ACD-14 TRMS-PLUS Clamp-on Multimeter With Dual Display Users Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com...
  • Page 2: Instrument Familiarization

    ➊ ➋ ➓ MAX 600A 600V CAT III HOLD ➌ ➒ © kM Hz ℉ ACD-14 PLUS © ➑ kM Hz ℉ ➍ SELECT ℉ ➐ ➎ ➏ Features of this instrument 1) Transformer Clamp Jaw for AC current magnetic field pick up...
  • Page 3: Warranty And Repair

    “Where to Buy” section on www.Amprobe.com for a list of distributors near you. Additionally, in the United States and Canada In-Warranty repair and replacement units can also be sent to a Amprobe® Test Tools Service Center (see next page for address). Non-Warranty Repairs and Replacement – US and Canada Non-warranty repairs in the United States and Canada should be sent to a Amprobe®...
  • Page 4: Table Of Contents

    ACD-14 PLUS & ACD-14 TRMS-PLUS Clamp-on Multimeter With Dual Display Contents Instrument Familiarization .................... 1 Warranty and Repair ....................... 2 Symbols ..........................3 Introduction........................4 Warnings and Precautions ....................4 Unpacking and Inspection ....................5 Operation ......................... 5 Maintenance and Troubleshooting ................. 9 Battery Replacement.
  • Page 5: Introduction

    Introduction The ACD-14 PLUS and ACD-14 TRMS-PLUS are digital clampmeters that measure both AC and DC voltage, AC current, Resistance, Frequency, Continuity and Diode Test. Frequency can be measured in the voltage and current modes. WARNINGS AND PRECAUTIONS Safety Information •...
  • Page 6: Unpacking And Inspection

    when the fuse blows in a circuit with open circuit voltage >1000 V // servicing CRT equipment. • Remove test leads before opening the case to change the battery. • Disconnect circuit power and discharge all high-voltage capacitors before testing resistance,continuity, diodes, or capacitance.
  • Page 7 Measuring AC Current - See Figure 3 1. Set the Function Switch to A position. 2. Open spring-loaded clamp by pressing the lever on left side of meter. 3. Position clamp around one wire or conductor and release the clamp lever. Make sure that the clamp is entirely closed.
  • Page 8 Continuity Testing - See Figure 5 1. Set the Function Switch to Ω and press the SELECT button until  is displayed. 2. Connect the test leads: Red to +, Black to COM. 3. Turn off power to the circuit being measured. 4.
  • Page 9 Measuring μA Current - See Figure 9 1. Set the Function Switch to and press the SELECT button for AC or DC is displayed. 2. Connect the test leads: Red to +, Black to COM. 3. Turn OFF power to the circuit being measured and break the circuit for connecting test leads.
  • Page 10: Maintenance And Troubleshooting

    FEATURES HOLD  / MAX  The HOLD feature freezes the display when the button is pressed. The MAX feature compares and displays the measured maximum value as fast as 30ms with auto-ranging capability. HOLD Press the HOLD button momentarily toggles to hold mode for the ACA function. To release the HOLD feature momentarily press the HOLD button.
  • Page 11: Battery Replacement

    Refer to the LIMITED WARRANTY section for obtaining warranty or service. Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. If the meter is not to be used for periods of longer than 60 days, remove the battery and store separately.
  • Page 12 AC bandwidth for non-sinusoidal waveforms Input Impedance: 10 MΩ, 30 pF nominal Transient protection: 6.5 kV (1.2/50μs surge) ACD-14 Plus: Average Sensing ACD-14 TRMS Plus: True RMS sensing - 5% to100 % of range...
  • Page 13 40.00, 400.0, 600 A ±( 1.5% rdg + 8 digits) Overload Protections: ACA Clamp-on jaws: 600 A rms continuous ACD-14 Plus: Average Sensing ACD-14 TRMS Plus: True RMS sensing - 10 % to 100 % of range 1) Max Induced error from adjacent current carrying conductor: 0.05 A 2) Specified accuracy is from 1% rdg to 100% rdg of range and for measurements made at the jaw center.
  • Page 14 Capacitance Range Accuracy 2) 3) 500.0nF, 5.000μF, 50.00μF, ±( 3.5% rdg + 6 digits) 500.0μF, 3000μF 1) Additional 50.00nF range accuracy is not specified 2) Accuracies with film capacitor or better 3) Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% rdg at low battery warning voltage of approximately 2.4V Transient protection:...
  • Page 15 Audible Continuity Tester Audible indication: between 10 Ω and 120 Ω. Transient protection: 6.5 kV (1.2/50 μs surge) Diode Tester / Open Circuit Voltage Test Current (Typical) < 1.6 VDC @ 0.25 mA Transient protection: 6.5 kV (1.2/50 μs surge) Max Hold* (where applicable) Specified accuracy ±...
  • Page 16: Figures

    Measuring DC Voltage MAX 600A 600V CAT III HOLD ACD-14 PLUS SELECT SELECT ℉ Black Figure 1...
  • Page 17 Measuring AC Voltage MAX 600A 600V CAT III HOLD ACD-14 PLUS SELECT SELECT ℉ Black Figure 2...
  • Page 18 Measuring AC Current and Frequency MAX 600A 600V CAT III HOLD ACD-14 PLUS SELECT ℉ Black Figure 3...
  • Page 19 Measuring Resistance MAX 600A 600V CAT III HOLD ACD-14 PLUS SELECT ℉ Black Figure 4...
  • Page 20 Continuity Testing MAX 600A 600V CAT III HOLD ACD-14 PLUS SELECT SELECT ℉ Black Figure 5...
  • Page 21: Testing Diodes

    Testing Diodes MAX 600A 600V CAT III HOLD ACD-14 PLUS SELECT SELECT ℉ Black Figure 6...
  • Page 22 Measuring Capacitance MAX 600A 600V CAT III HOLD ACD-14 PLUS SELECT SELECT ℉ Black Figure 7...
  • Page 23 Measuring Temperature MAX 600A 600V CAT III HOLD ACD-14 PLUS SELECT ℉ Figure 8...
  • Page 24 Measuring μA Current MAX 600A 600V CAT III HOLD ACD-14 PLUS SELECT ℉ Black Figure 9 Visit us at www.TestEquipmentDepot.com...

This manual is also suitable for:

Acd-14 trms-plus

Table of Contents