Preparation
Step 1-1 Viewing the typical installation
A typical installation will be similar to the one shown below.
Maximum pipe height
Maximum pipe length
Model
**07*******
**09*******
**12*******
Outdoor Unit
Outer wall
Indoor Unit
CAUTION
•
For the product that uses the R-32 refrigerant, Install the indoor unit on the wall 1.8 m or higher from the floor.
Evaporator/
fancoil (indoor)
Refrigerant lines,
electric, and drain
Pipe length
Minimum
Maximum
3
15
CAUTION
Cut insulation to have
rainwater drained
Make at least one round to
reduce noise and vibration.
Compressor/
condenser
(outdoor)
Standard for factory charge
5
Make a U-trap (A) on the pipe (which is connected to
the indoor unit) at outer wall and cut the bottom part of
the insulation (about 10 mm) to prevent rainwater from
CAUTION
getting inside through the insulation.
The actual units may look different from
the images depicted here.
(Unit : m)
Pipe height
Maximum
8
English
7