Specifications - Rheem 310 Series Service Instructions Manual

Table of Contents

Advertisement

SPECIFICATIONS

Storage Tank
Capacity (Litres)
Boost Mode Capacity (Litres)
Limp Mode Capacity (Litres)
Booster Element Rating (kW)
T&PR Valve Rating (kPa)
Maximum Inlet Water
Pressure (kPa)
Water Connections
Anode
Booster Element Controller Thermostat Setting
(Fixed)
Booster Element Mechanical Thermostat Setting
(Fixed)
Booster Element ECO Setting
Heat Pump Module
Parameter
Superheat Setting (Factory)
Refrigerant Type / Charge
Compressor Capacitor
Compressor Current Draw
Compressor Internal Overload
Setting (Automatic Reset)
Compressor Winding Resistance
High Pressure Switch
Fan Capacitor
Fan Winding Resistance
Salmson Circulator Winding
Resistance
Grundfos Circulator Winding
Resistance on Speed Setting 1
Grundfos Circulator Capacitor
Grundfos Circulator Speed Setting
1
HPS only applicable to models produced from 31/03/2016
TM025: 310 Series Heat Pump Service Instructions
Rev AF: Issued March 2016
This document is stored and maintained electronically by
Parameter
With ECV
Without ECV
Inlet / Outlet
Heat Pump
T&PR
Quantity
Length
1
Run Winding – Black & Brown:
551310
310
220
111
1.8 / 2.4 / 3.6
1000
680
800
Rp ¾" (20mm)
Rp ½" (15mm)
Rp ½" (15mm)
1153
62°C
70°C
88°C
180532 / 180552 / 180533 / 4000770009
6K at 10ºC saturated suction temperature
R134a / 1050 grams
35 µF +10/–5%, 370/440V AC, 50/60Hz
Cut Out:
Cut In:
Run Winding – Red & Blue:
Start Winding – Red & Black:
Cut out: 2930kPa (+/- 100kPa)
Manual reset to close < 2240kPa (+/- 200kPa)
2µF, 450V AC, 50/60Hz
Start winding – Black & Blue:
75.3Ω at 20ºC
602Ω at 20ºC
1.5µF +2/–5%
Technical Support. All printed copies are deemed uncontrolled.
Model
251310
310HAV
40467791
310
220
111
2.4 / 3.6
1000
680
800
Rp ¾" (20mm)
Rp ½" (15mm)
Rp ½" (15mm)
1
1153
62°C
70°C
88°C
6.4A
150°C
90°C
2.2Ω at 20ºC
3.3Ω at 20ºC
184Ω at 20ºC
238Ω at 20ºC
1
1
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents