Bryant ZONE PERFECT PLUS ZONEBB2KIT Installation Instructions Manual page 20

Hide thumbs Also See for ZONE PERFECT PLUS ZONEBB2KIT:
Table of Contents

Advertisement

EQUIPMENT
TWO-STAGE
CONTROLLER
FURNACE
N/A
DEF
DHUM
N/A
HUMIDIFY
HUM
N/A
O
N/A
B
24 VAC HOT
RH
RC
FAN
G
HEAT STAGE 2
W2
HEAT STAGE 1
W1
N/A
Y2
COOL STAGE 1
Y1
See note 12
→ Fig. 19—2-Stage Furnace
with 1-Speed Air Conditioner
EQUIPMENT
CONTROLLER
DEFROST
DEF
N/A
DHUM
HUMIDIFY
HUM
RVS COOLING
O
N/A
B
24 VAC HOT
RH
RC
FAN
G
HEAT STAGE 3
W2
HEAT STAGE 2
W1
N/A
Y2
COOL/HEAT STAGE 1
Y1
See notes 1, 2, 3, 6, 10, 11, and 12
→ Fig. 21—2-Stage Furnace
with 1-Single Speed Heat Pump (Dual Fuel)
SINGLE-
SPEED AIR
CONDITIONER
HUMIDIFIER
(24 VAC)
C
C
R
G
W2
W/W1
Y/Y2
Y
TWO-
SINGLE-
STAGE
SPEED HEAT
FURNACE
PUMP
HUMIDIFIER
(24 VAC)
O
C
C
R
R
G
W2
W2
W/W1
Y/Y2
Y
EQUIPMENT
CONTROLLER
N/A
N/A
HUMIDIFY
N/A
N/A
24 VAC HOT
FAN
HEAT STAGE 2
HEAT STAGE 1
COOL STAGE 2
COOL STAGE 1
A98093
EQUIPMENT
CONTROLLER
DEFROST
HUMIDIFY
RVS COOLING
N/A
24 VAC HOT
FAN
HEAT STAGE 4
HEAT STAGE 3
COOL/HEAT STAGE 2
COOL/HEAT STAGE 1
A98095
with 2-Speed Heat Pump (Dual Fuel)
—20—
TWO-STAGE
FURNACE
DEF
DHUM
HUMIDIFIER
HUM
(24 VAC)
O
C
B
RH
R
RC
G
G
W2
W2
W1
W/W1
Y2
Y/Y2
Y1
See notes 4 and 12
→ Fig. 20—2-Stage Furnace
with 2-Speed Air Conditioner
TWO-STAGE
FURNACE
DEF
HUMIDIFIER
(24 VAC)
DHUM
HUM
O
C
B
RH
R
RC
G
G
W2
W2
W1
W/W1
Y2
Y/Y2
Y1
See notes 1, 2, 3, 4, 6, 7, 8, 9, 10, 11, and 12
→ Fig. 22—2-Stage Furnace
TWO-SPEED
AIR CONDITIONER
C
R
Y2
Y1
A98094
TWO-
SPEED HEAT
PUMP
O
C
R
W2
Y2
W3
Y1
A98096

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents