Quick Start; Quick Programming Of Comfort Schedules - Bryant ZONE PERFECT PLUS ZONEBB2KIT Installation Instructions Manual

Hide thumbs Also See for ZONE PERFECT PLUS ZONEBB2KIT:
Table of Contents

Advertisement

SYSTEM TYPE
COOL 2
1-Speed AC
with 3-Stage Heat
2-Speed AC
with 3-Stage Heat
1-Speed HP
with 3-Stage Heat
2-Speed HP
Y1,Y2,O
with 3-Stage Heat
Y1,Y2,O
1-Speed Dual Fuel
2-Speed Dual Fuel
Y1,Y2,O
Fig. 14—Zone Perfect Plus Keypad Display

→ QUICK START

The quick start procedure outlined below will allow you to use
your zoning system before you learn all the details of system
operation. This setup may be done by the installer. For the best
comfort and energy-saving results, we recommend that you read
through the Owner's Manual and setup the system to match the
end-user's schedule and comfort requirements.
To begin, locate the User Interface and follow the steps outlined
below: (See Fig. 14.)
Set current day and time:
1. Press NEXT DAY button until current day of the week is
shown.
2. Press SET TIME/TEMP button until the TIME icon flashes.
3. Press UP or DOWN buttons until the desired time is shown,
making sure that the AM or PM time is correct.
4. Press HOLD/END key to exit.
Select system Mode:
1. Press MODE button to select HEAT or COOL.
2. Press HOLD/END button.
3. Press UP or DOWN button until the desired temperature is
displayed.
4. Press ALL ZONE button if this desired temperature is
needed for every zone. Otherwise press NEXT ZONE
button, and repeat HOLD function in selecting the desired
temperature for each zone.

→ QUICK PROGRAMMING OF COMFORT SCHEDULES

The following is a brief overview of how to access and program
schedules in your new zoning system. We highly recommend that
you read and follow the programming information provided in the
Owner's Manual for detail step-by-step instructions.
→ TABLE 1—OUTPUTS VS. STAGES
COOL 1
HEAT 1
N/A
Y1
N/A
Y1
Y1,Y2
Y1
Y1,Y2
Y1
N/A
Y1,O
N/A
Y1,O
Y1,O
Y1,O
N/A
Y1,O
Y1,O
A98134
HEAT 2
HEAT 3
W1
W1,W2
W1
W2
W1,W2
W1
W1,W2
W1
W2
W1,W2
Y1
Y1,W1
Y1,W1,W2
Y1
Y1,W1
Y1,W2
Y1
Y1,Y2
Y1,Y2,W1
Y1
Y1,Y2
Y1,Y2,W1
Y1
W1
W1,W2
Y1
Y1,Y2
Before proceeding, set the correct Time and Day at the User
Interface (see above Quick Start).
However, if you followed the above Quick Start procedure in
selecting the system mode, you will need to reverse the ALL
ZONE and/or HOLD functions before proceeding. Simply press
ALL ZONE and/or HOLD button to remove these icons from the
display. (See Fig. 14.)
During the programming process, you will have access to 4
program time periods, e.g., WAKE, DAY, EVE, and SLEEP. You
will be able to select program start times and the heat/cool set
points for each time period and zone. Use the Keypad to enter and
move around inside the program. Use the temperature UP and
DOWN buttons to adjust the start times and to raise and lower set
points. When inside the program, the blinking icon indicates that a
setting may now be changed.
1. Decide on a program schedule that you desire. Table 2 is an
example of what already exists in the User Interface as the
Energy Star recommended setting.table
TABLE 2—USER INTERFACE SETTINGS
WAKE
DAY
EVE
SLEEP
2. To begin programming, press PROGRAM button.
3. Press NEXT ZONE button until ZONE 1 appears on the
LCD display.
4. Press NEXT DAY button until Monday (Mo) is displayed.
5. Press NEXT PERIOD button until the WAKE period is
displayed.
6. Press SET TIME/TEMP button until the TIME icon is
flashing.
7. Start programming ZONE 1 beginning with the WAKE
start time. Press the UP or DOWN button until the desired
starting time is displayed, make sure that the AM is correct.
8. Press SET TIME/TEMP button until the HEAT icon is
flashing. Press UP or DOWN button until the desired
heating temperature for that period is displayed.
9. If that zone is going to be unoccupied, press OUT button.
For more information regarding the Out feature, read the
following section pertaining to Hold, Off, Out, and All
Zone.
10. Press SET TIME/TEMP button until the COOL icon is
flashing. Press UP or DOWN button until the desired
cooling temperature for that period is displayed. You have
now programmed the time and desired heating and cooling
temperatures for Monday, ZONE 1, in the WAKE time
period.
—16—
HEAT 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Y1,W1,W2
Y1,Y2,W1,W2
Y1,Y2,W2
N/A
W1
W1,W2
TIME
COOL
6:00 AM
78
8:00 AM
85
5:00 PM
78
10:00 PM
82
HEAT 5
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Y1,Y2,W1,W2
N/A
N/A
HEAT
68
60
68
60

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents