Carrier 50JZ024 Installation, Start-Up And Service Instructions Manual page 17

Single-package heat pump units with puron (r-410a) refrigerant
Table of Contents

Advertisement

UNIT
MOTOR SPEED
Watts
Low
Cfm
Watts
024
Med
Cfm
Watts
High
Cfm
Watts
Low
Cfm
Watts
30
Med
Cfm
Watts
High
Cfm
Watts
Low
Cfm
Watts
36
Med
Cfm
Watts
High
Cfm
Watts
Low
Cfm
Watts
42
Med
Cfm
Watts
High
Cfm
Watts
Low
Cfm
Watts
48
Med
Cfm
Watts
High
Cfm
Watts
Low
Cfm
Watts
60
Med
Cfm
Watts
High
Cfm
* Air delivery values are based on operating voltage of 230v or 460v, wet coil, without filter or electric heater. Deduct filter and electric heater pressure drops to obtain
static pressure available for ducting.
NOTES:
1. Do not operate the unit at a cooling airflow that is less than 350 cfm for each 12,000 Btuh of rated cooling capacity. Evaporator coil frosting may occur at airflows below
this point.
2. Dashes indicate portions of table that are beyond the blower motor capacity or are not recommended.
3. Deduct 10% for 208v.
UNIT SIZE
FILTER SIZE
50JZ
500
024, 030
20x20x1
0.05 0.07 0.08 0.10 0.12
036
20x24x1
-
042, 048, 060
24x30x1
-
DEFROST — The defrost control is a time/temperature control
which includes a field-selectable time period (DIP switch 1 and 2
on the board) between defrost cycles of 30, 60, 90, or 120 minutes
(factory set at 30 minutes).
To initiate a forced defrost, two options are available depending on
the status of the defrost thermostat.
If defrost thermostat is closed, speedup pins (J1) must be shorted
by placing a flat head screw driver in between for 5 sec and
releasing, to observe a complete defrost cycle. When the Quiet
Shift switch is selected, compressor will be turned off for two 30
Table 4—Wet Coil Air Delivery
Unit 50JZ 024-060 (Deduct 10% for 208v)*
0.0
0.1
0.2
275
273
271
923
844
754
-
-
-
-
-
-
-
-
-
-
-
-
276
276
272
963
929
781
375
377
371
1202
1170
1079
-
-
-
-
-
-
462
451
431
1374
1290
1205
523
506
490
1500
1408
1301
-
645
628
-
1474
1369
660
639
524
1701
1659
1618
-
-
-
-
-
-
-
-
-
-
-
-
620
600
586
1662
1621
1581
763
747
729
1917
1868
1822
-
-
-
-
-
-
597
592
578
2265
2190
2101
754
730
707
2383
2282
2202
901
876
856
2480
2383
2301
Table 5—FILTER PRESSURE DROP
600
700
800
900
1000 1100 1200 1300 1400 1599 1600 1700 1800 1900 2000 2100 2200 2300
0.13
0.14
-
-
-
0.09
0.10
0.11
-
-
-
-
-
-
EXTERNAL STATIC PRESSURE (IN. WG)
0.3
0.4
0.5
0.6
270
-
-
669
-
-
359
353
350
347
941
876
814
737
-
-
-
447
-
-
-
968
-
-
-
-
-
-
362
354
350
976
884
807
-
469
449
435
-
1174
988
828
411
394
381
1116
1020
916
471
449
426
1190
1082
977
610
595
584
575
1267
1169
1069
962
611
598
583
564
1576
1531
1481
1425
-
-
704
675
-
-
1701
1631
-
-
-
-
-
-
574
562
548
530
1540
1496
1447
1392
709
686
661
634
1774
1722
1662
1594
852
832
809
784
1982
1914
1839
1757
526
460
452
445
2033
1974
1869
1614
687
671
658
646
2134
2070
2005
1935
836
813
785
755
2233
2175
2122
2066
(In. wg)
CFM
0.15
-
-
-
-
0.13
0.14
0.15
0.16
-
0.07
0.08
0.09
0.10
0.11
sec intervals during this complete defrost cycle, as explained
previously. When Quiet Shift switch is in factory default OFF
position, a normal and complete defrost cycle will be observed.
If defrost thermostat is in open position, and speedup pins are
shorted (with a flat head screw driver) for 5 sec and released, a
short defrost cycle will be observed (actual length is dependent
upon the selected Quiet Shift position). When Quiet Shift switch is
in ON position, the length of defrost is 1 minute (30 sec
compressor off period followed by 30 sec of defrost with com-
pressor operation). On return to heating operation, compressor will
17
0.7
0.8
0.9
-
-
-
-
-
-
-
-
341
-
-
622
-
-
439
431
423
869
765
659
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
428
-
-
718
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
541
518
495
1363
1293
1223
645
614
582
1550
1460
1361
-
806
777
749
-
1708
1614
1521
510
487
-
1331
1263
-
606
577
547
1515
1427
1330
757
730
704
1669
1577
1486
-
-
-
-
-
-
630
603
558
1858
1771
1667
723
696
681
1998
1910
1788
-
-
-
-
-
-
-
-
-
-
0.12
0.13
0.14
0.15
0.16
1.0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
473
1154
550
1256
726
1435
-
-
517
1227
682
1402
-
-
486
1576
687
1619
-
-
-
-
0.17
0.18