Vector TCY-BH-U Manual

Intelligent humidistat
Hide thumbs Also See for TCY-BH-U:

Advertisement

Quick Links

TCY-BH-U Intelligent humidistat
Features
Low power energy consumption: < 1W per unit.
Relays switching for outputs each up to 2(1.2)A.
Humidity control for humidifying and de-humidifying.
Option for fan supported devices.
Cost saving option with Economy functionality and set point limitations.
External sensor input for setpoint setback based on outdoor temperature.
Control binary humidifiers and dehumidifiers with or without fan support.
Temperature display of external input in Celsius or Fahrenheit.
Password protected programmable user and control parameters:
Setpoint range limitation.
o
Access control for setpoints and mode change.
o
Access control for clock and time programs.
o
Select your display contents.
o
Selectable behavior after return from power failure.
o
Deluxe Version:
Clock and time schedule functions
Blue backlight for LCD
Applications
Humidifiers:
On / Off type humidifiers
On / Off type humidifiers with single speed fan support
Dehumidifiers:
On / Off type dehumidifiers
On / Off type dehumidifiers with single speed fan support
Combination humidifiers and dehumidifiers without fan support
General Description
The TCY-BH-U is a stand-alone electronic binary humidity stat. The TCY-BH-U features one internal humidity sensor, one
external NTC temperature sensor input and two binary outputs (Relays).
A detailed parameterization is possible with the use of a simple configuration routine. The TCY-BH-U can be configured using
the standard operation terminal. No special tools or software is required.
Ordering
Item Name
Item code
TCY-BH-U
40-10 0055
TCY-BH-U-W04
40-10 0055-04
TCY-BH-U-W05
40-10 0055-05
TCY-BH-U-D
40-10 0056
TCY-BH-U-D-W04
40-10 0056-04
TCY-BH-U-D-W05
40-10 0056-05
Accessories
S-Tn10-2
40-20 0001
SD-Tn10-12-2
40-20 0002
SD-Tn10-20-2
40-20 0003
SDB-Tn10-12
40-20 0051
SDB-Tn10-20
40-20 0004
SOA-Tn10
40-20 0006
AES-HT-A5
40-50 0031-5
Doc:70-07-0102, V1.1, Date: 20100504
Subject to alteration
Variant
Features
standard
Binary controller with:
humidifying
1 Internal humidity input
de-humidifying
1 external temperature input (For set point shift)
Deluxe
1 DO (Relay) for humidifier or dehumidifier
humidifying
1 DO (Relay) for fan (optional)
de-humidifying
Flying lead sensor with 2 m cable
Flying lead duct sensor 12cm immersion depth, 2m cable
Flying lead duct sensor 20cm immersion depth, 2m cable
Duct sensor with housing, 12cm immersion depth
Duct sensor with housing, 20cm immersion depth
Outdoor sensor
Replacement humidity sensor 5% accuracy
© Vector Controls GmbH, Switzerland
Humidistat TCY-BH-U
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Vector TCY-BH-U

  • Page 1 NTC temperature sensor input and two binary outputs (Relays). A detailed parameterization is possible with the use of a simple configuration routine. The TCY-BH-U can be configured using the standard operation terminal. No special tools or software is required.
  • Page 2: Technical Specification

    112 x 73 x 15 mm (4.4” x 2.9” x 0.6”) Power case: ø 58 x 32 mm (ø 2.3” x 1.3”) Weight (including package) 270g Doc:70-07-0102, V1.1, Date: 20100504 © Vector Controls GmbH, Switzerland Page 2 Subject to alteration...
  • Page 3: Wiring Diagram

    Binary output 1: if CP11 = ON: Fan 0…24 VAC or 0…30 VDC Binary output 2: De-humidify 0…24 VAC or 0…30 VDC Temperature input for setback: NTC 10kΩ @ 25°C (77°F) Doc:70-07-0102, V1.1, Date: 20100504 © Vector Controls GmbH, Switzerland Page 3 Subject to alteration...
  • Page 4: Connection Terminals

    With a Philips-type screw driver of size #2, carefully tighten the front holding screw to secure the front part to the mounting plate. This screw is located on the front lower side of the unit. There is no need to tighten the screw too much. Doc:70-07-0102, V1.1, Date: 20100504 © Vector Controls GmbH, Switzerland Page 4 Subject to alteration...
  • Page 5: Display And Operation

    The clock symbol will be displayed if time programs are activated. Note: Time programs will not operate if operation mode is set to OFF by remote control, or if time is not set. Doc:70-07-0102, V1.1, Date: 20100504 © Vector Controls GmbH, Switzerland Page 5 Subject to alteration...
  • Page 6: Error Messages

    Clock Operation and Time Schedules (Deluxe Version) TCY-BH-U-D contains a real time clock. Up to 16 mode changes (not defined, Off, Economy, Comfort, University mode) based on weekdays and time may be programmed. See chapter operation on how to program switch times.
  • Page 7: Accessing Advanced Settings

    Select switching time 00:00 to 23:45 in 15-minute steps; press OPTION to continue. Repeat steps 3 and 4 for each switching time. Access to time schedules may be disabled with UP-04 Doc:70-07-0102, V1.1, Date: 20100504 © Vector Controls GmbH, Switzerland Page 7 Subject to alteration...
  • Page 8 Humidistat TCY-BH-U Setting of user parameters The TCY-BH-U can be adapted to fit perfectly into your application. The control operation is defined by parameters. The parameters are set during operation by using the control buttons. The parameters may only be accessed by entering a code. There are two levels of parameters: User operation parameters for access control settings, and Expert parameters for control functions and unit setup.
  • Page 9: Control Functions

    CP17. The full temperature setback is reached when the temperature reaches the full limit CP16. The actual set point will in this case be equal to the TSET setpoint. Temperature setback may be enabled with CP14. Setpoint Temperature Setback CP15 T [°C, F] CP16 CP17 Doc:70-07-0102, V1.1, Date: 20100504 © Vector Controls GmbH, Switzerland Page 9 Subject to alteration...
  • Page 10: Output Configuration

    Control speed will slow down when a large number of samples are used for an averaging signal. This should be taken into account when defining the control parameters. Doc:70-07-0102, V1.1, Date: 20100504 © Vector Controls GmbH, Switzerland Page 10 Subject to alteration...
  • Page 11 Humidistat TCY-BH-U Configuration parameters for firmware version 1.1 The TCY-BH-U can be adapted to wide variety of applications. The adaptation is done with parameters. The parameters can be changed on the unit without the need of additional equipment. Identifying the firmware version The parameters and functionality of controller depend on its firmware revision.

Table of Contents