5.6

Notes on connecting/disconnecting cables

CAUTION!
Always read the documentation supplied with the device you wish to
connect.
Never connect, or disconnect cables during a thunderstorm.
Never pull on a cable when disconnecting it. Always take hold of the
cable by the plug.
Follow the sequence described below to connect or disconnect external
devices to or from the server:
Be sure to wait for 10 seconds or more after shutdown before turning the
server on.
Connecting cables
Turn off all power and equipment switches.
Disconnect all power plugs from the properly grounded power outlets.
Connect all cables to the server and peripherals.
Plug all data communication cables into the utility sockets.
Plug all power cords into the properly grounded power outlets.
Disconnecting cables
Turn off all power and equipment switches.
Disconnect all power plugs from the properly grounded power outlets.
Unplug all data communication cables from the utility sockets.
Disconnect the relevant cables from the server and all the peripherals.
For connecting or disconnecting LAN cables, the server needs not be
powered off. To avoid loss of data teaming/bonding function has to be
enabled.
5.7

Notes on inserting/removing units

Please power off the system and remove the power cords from PSUs in
the chassis before inserting or removing System Board, IOUB, DU_SAS,
DU_PCIE, MGMT-LANU or PCIe card except PHP slot to/from the
chassis.