The "Ident Profile" Block - Siemens SIMATIC RF120C Operating Instructions Manual

Rfid systems communications module with application blocks for s7-1200 and s7-1500
Hide thumbs Also See for SIMATIC RF120C:
Table of Contents

Advertisement

AdvancedCmd and Ident profile
C.2 The "Ident profile" block
Table C- 2
Command
Write
Read
MEM-Status
DEV-Status
Inventory
Format
1)
2)
As an alternative, the settings possible with the "AdvancedCmd" function block can also be
made with the Ident profile (see section "The "Ident profile" block (Page 88)").
C.2

The "Ident profile" block

Note
Parallel operation using the FB and Ident profile is not possible
The RF120C communications module must not be operated using the function blocks and
the Ident profile at the same time.
88
Permitted settings for the "CMD" parameter
CMD_ID
71h
70h
73h
74h
69h
66h
Details: See Function manual for RF620R/RF630R. There, the DEV status corresponds to the
"SLG-Status" command and Inventory corresponds to the "GET" command.
The attributes must be compiled as follows: 81h → 01h, 82h → 02h, 83h → 03h, 85h → 05h, 87h →
07h, 90h → 10h, 91h → 11h, 92h → 12h, A0h → 20, A01 → 21
Details: refer to the Function manual for the RFID standard profile
LEN_DATA
Length of the data
to be written
Length of the data
to be read
-
-
-
Value: 15
The memory size
and the
initialization value
must be stored in
the data buffer
2)
Communications module RF120C with application blocks for S7-1200 and S7-1500
Operating Instructions, 07/2013, C79000-G8976-C328-01
Parameter
ADR_TAG
ATTR
Address on the
-
transponder
Address on the
-
transponder
-
RF200: 83h
RF300: 82h, 83h
RF600: 84h, 85h
MOBY D: 83h
-
RF200: 81h
RF300: 81h, 86h
RF600: 87h, 88h, A0h,
A1h
MOBY U: 81h, 84h
MOBY D: 81h
-
RF600: 82h, 83h, 85h,
90h, 91h, 92h, A0h, A1h
1)
-
-
1)