P15 = 2 or 3 Immediate Regeneration
Override
In addition to delayed regenerations automatic
regenerations will occur at any time during the day if the
capacity remaining reaches zero.

Immediate Regeneration Only Option

Automatic regenerations performed at the time of
regeneration (P2) can be eliminated by setting the
control for fixed reserve with immediate regeneration
override (P15 = 3) and setting the reserve capacity
percentage (P16) to 0%. This will create a reserve
capacity of zero gallons and override the Time of
Regeneration (P2) to allow for an immediate
regeneration. These are the preferred settings for a
Twin Alternating softener system.

Advance Cycle Function

While in a regeneration cycle, you can advance the
stager to the next cycle by pressing and holding the left
arrow key (←) for 3 seconds. The stager and controller
will then advance to the next regeneration cycle.

Cancel Regeneration Function

To cancel (abort) a regeneration, press and hold the left
arrow (←) and SET keys for 3 seconds. The control will
display an ERROR 3 and return the stager to the
service (Home) position. Once in the service position,
ERROR 3 will be cleared.