Assembling

4.1

General requirements

Mounting options
SIMOTION D410 comes in two designs:
● Mounted on the power module: SIMOTION D410 is mounted on the PM340 power
● Operation away from the power module: SIMOTION D410 is mounted on a mounting
Open device
SIMOTION D410 is an open device! This means, you can only install the modules in
housings, cabinets or electrical equipment rooms. These may only be accessible via key or
tool. Housings, cabinets, or electrical equipment rooms may only be accessed by trained or
authorized personnel. An external fire-protection housing is required.
The system must be without power when you mount the housing.
4.2

SIMOTION D410 mounted on the power module

Overview
A SIMOTION D410 can be snapped directly on to a SINAMICS S120 PM340 Power Module
in blocksize format via the PM-IF interface. Operation with SINAMICS G120 PM2x0 Power
Modules or Booksize Motor Modules is not possible.
Note
You can connect a PM340 blocksize power module to the DRIVE-CLiQ interface of
SIMOTION D410 using the CUA31/CUA32 adapter module. Power Modules in chassis
format AC/AC are connected to SIMOTION D410 via the DRIVE-CLiQ interface of the power
module.