Operation - Hilti TE 50 User Manual

Hide thumbs Also See for TE 50:
Table of Contents

Advertisement

Available languages

Available languages

If the device is powered by a generator or transformer, the generator or
transformer's power output must be at least twice the rated input power
shown on the rating plate of the device. The operating voltage of the
transformer or generator must always be within +5 % and -15 % of the rated
voltage of the device.
Weight (without supply cord)
Storage temperature
Ambient temperature for operation
Ø hammer drill bits
Ø hammer drill bits
Ø drill bits for wood
Ø drill bits for wood
Ø drill bits for metal
Ø drill bits for metal
5

Operation

5.1 Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or
before changing accessories.
Observe the safety instructions and warnings in this documentation and on
the product.
5.1.1 Fitting the side handle
1. Release the side handle clamping band by turning the handle grip.
2. Slide the side handle clamping band over the chuck from the front and
into the recess provided.
3. Bring the side handle into the desired position.
4. Tighten the side handle clamping band by turning the handle grip.
8
English
Printed: 14.12.2018 | Doc-Nr: PUB / 5283567 / 000 / 03
3
2102963
TE 50­AVR
13.4 lb
(6.1 kg)
−4 ℉ ... 158 ℉
(−20 ℃ ...
70 ℃)
1 ℉ ... 140 ℉
(−17 ℃ ...
60 ℃)
1/2 in ...
1 1/4 in
12 mm ...
32 mm
1/4 in ...
1 3/8 in
6 mm ... 35 mm
1/4 in ... 1/2 in
6 mm ... 13 mm
*2102963*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Te 50-avr

Table of Contents