LG LW240CE Owner's Manual page 15

Table of Contents

Advertisement

Available languages

Available languages

How to Install the Unit
1
To prevent vibration and noise, make sure the unit
is installed securely and firmly.
2
Install the unit where the sunlight does not shine
directly on the unit.
3
There should be no obstacles, such as a fence and
wall, within 20" from the back of the cabinet
because it will prevent heat radiation of the
condenser.
Restriction of outside air will greatly reduce the
cooling efficiency of the air conditioner.
CAUTION
: All side louvers of the cabinet must remain exposed to the outside of the structure.
4
Install the unit a little slanted so the back is slightly lower than the front (about 1/2").
This will force condensed water to flow to the outside.
5
Install the unit with the bottom about 30"~60" above the floor level.
Window Requirements
NOTICE
: All supporting parts should be secured to firm wood, masonry,
or metal.
• This unit is designed for installation in standard double hung
windows with actual opening widths from 29"
to 41".
• The top and bottom window sash must open sufficiently to
allow a clear vertical opening of 19" from the bottom of the
upper sash to the window stool.
Awning
Cooled air
29" to 41"
19" min.
Inner sill
Interior wall
26" min.
(Without frame curtain)
Hardware Installation
Fence
Heat
radiation
About
1
/
"
2
Over 20"
Sash
Window
Offset
Sill
Exterior
Owner's Manual 15

Advertisement

Table of Contents
loading

Table of Contents