Cleaning The Wall Extra I-Spray Spray Attachment - WAGNER W 890 FLEXIO Original Operating Instructions

Universal sprayer
Table of Contents

Advertisement

W 890 Flexio
Clean the air cap, nozzle seal and nozzle with a brush and solvent or water.
4) Clean the outside of the spray gun and container with a cloth soaked in solvent or
water.
5) Assemble the parts again (see "Assembly").
Assembly
Attention! Never operate the device if the nozzle seal is either damaged or
missing. If the nozzle seal is either missing or damaged liquids can enter
the device and increase the risk of an electric shock.
1) Push the nozzle seal (fig. 18, 1) over the needle (3); the groove (slot) should point
towards you.
2) Put the nozzle (fig. 18, 2) onto the gun body and find the correct position by turning it.
3) Put the air cap onto the nozzle and tighten it using the union nut.
4) Place the container seal from below on the suction tube and slide it over the collar,
while turning the container seal slightly.
5) Insert the suction tube with container seal in the gun body.
In order to mount the gun more easily apply lubricating grease (enclosed) liberally to
the O-ring at the spray attachment (Fig. 24, 5) and to the O-ring of the plug connection
of the air hose (Fig. 26, 2).
20. Cleaning the Wall Extra I-Spray
spray attachment
1) Screw of the container and empty it. Pull out the suction tub with container seal.
CAUTION!
Never clean seals, diaphragm and nozzle or air holes of the spray gun with metal
objects.
The ventilation hose and diaphragm are only solvent-resistant to a limited
extent. Do not immerse in solvent, only wipe.
2) The unit may only be operated with an integer diaphragm (Fig. 16, C). If any
paint has penetrated to the ventilation hose, check and clean the membrane (see the
Maintenance chapter).
3) Move the air cap (Fig. 19, 1) to the vertical position for easier removal and lift it off.
4) Unscrew the union nut (fig. 19, 2). Clean the air cap (1) and nozzle (3) with a brush and
solvent or water.
Attention! Never remove the red nozzle seal from the nozzle. If the nozzle
seal is either missing or damaged liquids can enter the device and increase
the risk of an electric shock.
5) Clean the outside of the spray gun and container with a cloth soaked in solvent or
water.
6) Assemble the parts again (see "Assembly").
GB
33

Hide quick links: