Troubleshooting - Sun Microsystems SPARCstorage DLT 4000 Manual

Table of Contents

Advertisement

1

Troubleshooting

6
If the DLT4000 tape drive fails during POST or operation, use Table 1-1 to
determine the problem and the action to take.
Table 1-1
Troubleshooting
Symptom:
Your system does not recognize the DLT4000 tape drive.
Action:
Make sure that:
The SCSI ID is unique.
The SCSI data cable is not loose.
The SCSI bus is correctly terminated.
You have rebooted the system using the boot -r command.
Symptom:
All LEDs on the right- or left-side of the tape drive front panel
blink.
Action:
Try to unload the tape and reinitialize the drive by pressing the
Unload button, or turn the drive power off and then on again.
The right- or left-side LEDs stop blinking and the drive tries to
reinitialize. The LEDs should turn on steady again and go off if
the test succeeds.
If all right- or left-side LEDs still blink, the drive has a hardware
failure.
20-40 Gbyte SPARCstorage DLT4000 Tape Drive Manual—February 1997