Operation - Caldertech 02-31-650 Operating Instructions Manual

Hydraulic squeeze off tool, 63-180mm / 2”-6” / 63-200mm
Table of Contents

Advertisement

Operating Instructions
03.
Hydraulic Squeeze Off Tool 180mm / 6" IPS / 200mm

Operation

Squeeze Tool
Main Frame
Hydraulic Jack
Jack Handle
Hydraulic Jack
Control Valve
Instructions for Use
1. Unscrew the 2 check screws until the threads are clear of the
threaded blocks.
2. Locate the pressure control valve on the hydraulic jack. The tip of
the jack handle will connect onto this. Unscrew the control valve
until any internal pressure in the jack is released. The jack and
squeeze bar assembly will be retracted under the pressure of the
return springs.
3. Remove the Bottom bar from the loops in the mainframe.
4. Set the limit stop (buffer) plates to the correct pipe diameter and
rating (SDR) of the pipe to be squeezed. If the plates do not have the
correct sizes, check the other set exchange if necessary. The plates
03. Operation
Hydraulic Jack
Pump Collar
Safety Check
Screw Blocks
Safety Check
Screws
Limit Stop
Plates
Bottom Bar