Safety Considerations - Trane 4DCY4024 Installer's Manual

Single packaged dual fuel 14 seer convertible, 2 - 5 ton, 64 - 120 mbtu r-410a
Hide thumbs Also See for 4DCY4024:
Table of Contents

Advertisement

Installer's Guide

Safety Considerations

IMPORTANT: Read this entire manual before beginning installation procedures.
NOTICE
Warning and Cautions appear at appropriate
locations throughout this guide. Read these
carefully.
WARNING: INDICATES A POTENTIALLY HAZ-
ARDOUS SITUATION WHICH, IF NOT AVOID-
ED, COULD RESULT IN DEATH OR SERIOUS
INJURY.
CAUTION: Indicates a potentially hazardous situation
which, if not avoided, may result in minor or moderate in-
jury. It may also be used to alert against unsafe practices
and where property-damage-only accidents could occur.
!
This product contains fiberglass wool insulation! Fiberglass
dust and ceramic fibers are believed by the state of California
to cause cancer through inhalation. Glasswool fibers may
also cause respiratory, skin, or eye irritation.
PRECAUTIONARY MEASURES
• Avoid breathing fiberglass dust
• Use a NIOSH approved dust/mist respirator
• Avoid contact with the skin or eyes. Wear long-sleeved,
loose fitting clothing, gloves, and eye protection.
• Wash clothes separately from other clothing, rinse
washer thoroughly.
• Operations, such as sawing, blowing, tear-out, and
spraying may generate fiber concentrations requiring
additional respiratory protection. Use the appropriate
NIOSH approved respirator in these situations.
FIRST AID MEASURES
Eye Contact:
Flush eyes with water to remove
dust. If symptoms persist, seek medical
attention.
Skin Contact:
Wash affected area gently with soap and
warm water after handling.
!
EXPLOSION HAZARD!
Propane gas is heavier than air and may collect in any low
areas or confined spaces. In addition, odorant fade may make
the gas undetectable except with a warning device. If the
gas furnace is installed in a basement, an excavated areas
or a confined space, it is strongly recommended to contact
a gas supplier to install a gas detecting warning device in
case of leak. The manufacturer of your furnace does not test
any detectors and makes no representations regarding any
brand or type of detector.
!
EXPLOSION HAZARD!
To prevent an explosion or possible injury, death, and equip-
ment damage, do not store combustible materials, gasoline,
or other flammable vapors or liquids near the unit.
Page 2
WARNING
WARNING
WARNING
!
CONTAINS REFRIGERANT!
SYSTEM CONTAINS OIL AND REFRIGERANT UNDER
HIGH PRESSURE. RECOVER REFRIGERANT TO RELIEVE
PRESSURE BEFORE OPENING SYSTEM. Failure to follow
proper procedures can result in personal illness or injury
or severe equipment damage.
!
Unit contains R-410A Refrigerant!
R-410A operating pressure exceeds the limit of R-22. Proper
service equipment is required. Failure to use proper service
tools may result in equipment damage or personal injury.
SERVICE
Use only R-410A Refrigerant and approved POE compres-
sor oil.
!
Improper Unit Lift!
Test lift unit approximately 24 inches to verify proper center
of gravity lift point. To avoid dropping of unit, reposition
lifting point if unit is not level. Failure to properly lift
unit could result in death or serious injury or possible
equipment or property-only damage.
!
RECONNECT ALL GROUNDING DEVICES.
All parts of this product that are capable of conducting
electrical current are grounded. If grounding wires, screws,
straps, clips, nuts, or washers used to complete a path to
ground are removed for service, they must be returned to
their original position and properly fastened.
!
Hot Surface!
Do Not touch top of compressor. May cause minor to severe
burning.
CAUTION
!
Never use combustible cleaning fluids on any part of the
furnace.
IMPORTANT: This product has been designed and manufactured to meet
ENERGY STAR criteria for energy efficiency. However, proper refrigerant
charge and proper air flow are critical to achieve rated capacity and efficiency.
Installation of this product should follow the manufacturer's refrigerant charging
and air flow instructions. Failure to confirm proper charge and airflow may
reduce energy efficiency and shorten equipment life.
IMPORTANT: Do not connect gas piping to the unit until a line pressure test
has been completed. This unit should never be exposed to gas line pressure in
excess of 14 inches water column (1/2 PSIG). The furnace and its equipment
shutoff valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psi.
IMPORTANT: Reconnect all grounding devices. All parts of this product capable
of conducting electrical current are grounded. If grounding wires, screws, straps,
clips, nuts, or washers used to complete a path to ground are removed for service,
they must be returned to their original position and properly fastened.
IMPORTANT: Wear appropriate gloves, arm sleeve protectors, and eye
protection when servicing or maintaining this equipment.
WARNING
WARNING
WARNING
CAUTION
CAUTION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4dcy40604dcy40484dcy40424dcy40304dcy4036

Table of Contents