Wiring The Breakout Box - American Dynamics Illustra 625 PTZ Quick Reference Manual

Breakout box
Hide thumbs Also See for Illustra 625 PTZ:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11

Wiring the Breakout Box

This guide assumes that cables have been pulled to the site.
Step
Action
For outdoor installations, remove the four watertight cord grip fittings and replace with
1
appropriately rated 20mm conduit needed for outdoor use. Fit seals/glands in accordance
with conduit manufacturer's instructions.
Feed the alarm and audio cables through the conduit and connectors.
2
Terminate the alarm and audio wires using the provided connectors.
3
The pin out details are printed on the circuit board in the breakout box and are detailed in
Figure 2.
Brown
Red
Orange
Yellow
Green
Blue
Violet
Grey
White
Black
Cyan
Magenta
GND
Replace the cover on the breakout box and secure with the provided screws.
4
Figure 2
Alarms
RS485_0_A
RS485_0_B
RS485_1_A
RS485_1_B
ALARM0
ALARM1
ALARM2
ALARM3
RELAY_C
GND
RELAY_NO
RELAY_NC
GND
IN
OUT
Alarm Cable
IN/OUT
Audio
- End -
English Illustra 625 PTZ Breakout Box
Audio
WHT-AUD_OUT
BLK-AUD_GND
WHT-MIC_IN
BRN-M_BIAS
SCREEN
AUDIO_GND
SPARE1
SPARE2
IN
OUT
Audio Cable
IN/OUT
WHT-AUD_OUT
BLK-AUD_GND
WHT-MIC_IN
BRN-M_BIAS
SCREEN
AUDIO_OUT
AUDIO_GND
MIC_IN
MIC_BIAS
SCREEN
AUDIO_GND
SPARE1
SPARE2
1-3