INSTALLATION METHOD
Drilling a Hole in the Wall
Drill a hole of 60mm in diameter to the outside.
The drilling should be done at a distance of less than
200mm from the floor facing the indoor unit.
Drain Hose
Extend the drain hose to the drain hose connected to
the drain pan, and fix it with the tape or a cable-tie to
prevent separation. Then make a covering of it so
that water cannot flow outwardly.
Vinyl Chloride(Inner diameter ø18mm,
Piping Material
Insulator
Foamed Polyethylene
CAUTION
1. As the draining is of natural drain type, make the drain hose direct
downward.
2. If there is any foreign substance in the drain plate, it may clog the
drain pipe. Therefore, be sure to remove the foreign substance
inside after installation.
3. After completion of installation, be sure to pour water into the drain
pan, and then check the draining condition.
(There is no problem in draining when the draining is completed
within 20 seconds.)
12
E-
Outer diameter ø23mm)
Less than
200mm
Drain pan
Insulation
Band
Drain hose
Ø 60mm
Indoor and outdoor
connection