Carrier 58SU0A Installation, Start-Up, Operating And Service And Maintenance Instructions page 16

4-way multipoise induced-combustion 80% gas furnace
Table of Contents

Advertisement

Wire Lead
Wire Lead
Furnace
2
Color
Gray
Cooling. Do not use for heating.
Yellow
Alt Cooling or alt Heating
060­16
Orange
Alt Cooling or alt Heating
Blue
Heating or alt cooling
Red
Alt Cooling or alt Heating
Gray
Cooling. Do not use for heating.
Yellow
Alt Cooling or alt Heating
Alt Cooling or alt Heating
Orange
080­20
Blue
Heating or alt cooling
Red
Alt Heating or alt cooling
1. A filter is required for each return-air inlet. Airflow performance included 3/4-in. (19 mm) washable filter media such as contained in factory-authorized
accessory filter rack. To determine airflow performance without this filter, assume an additional 0.1-in. W.C. available external static pressure.
2. Adjust the blower speed tabs as necessary for the proper air temperature rise for each installation.
NOMINAL IRON
PIPE
SIZE IN. (mm)
1/2 (13)
3/4 (19)
1 (25)
1-1/4 (32)
1-1/2 (38)
* Cubic ft. of natural gas per hr for gas pressures of 0.5 psig (14-In. W.C.) or less and a pressure drop of 0.5-In. W.C. (based on a 0.60 specific gravity
gas). Ref: Chapter 6 current edition of ANSI Z223/NFPA 54.
Piping should be pressure and leak tested in accordance with
NFGC in the United States, local, and national plumbing and gas
codes before the furnace has been connected. After all
connections have been made, purge lines and check for leakage at
furnace prior to operating furnace.
If pressure exceeds 0.5 psig (14−In. W.C.), gas supply pipe must
be disconnected from furnace and capped before and during
supply pipe pressure test. If test pressure is equal to or less than
0.5 psig (14−In. W.C.), turn off electric shutoff switch located on
furnace gas control valve and accessible manual equipment
shutoff valve before and during supply pipe pressure test. After
all connections have been made, purge lines and check for
leakage at furnace prior to operating furnace.
The gas supply pressure shall be within the maximum and
minimum inlet supply pressures marked on the rating plate with
the furnace burners ON and OFF.
Table 5 – Air Delivery − CFM (With Filter)
Function
0.1
1720
1470
1305
1040
1135
0.1
2185
1885
1565
1365
1205
Table 6 – Maximum Capacity of Pipe*
INTERNAL
DIAMETER
In. (mm)
10
0.622 (16)
175 (53)
0.824 (21)
360 (110)
1.049 (27)
680 (207)
1.380 (35)
1400 (427)
1.610 (41)
2100 (640)
Test Airflow Delivery @ Various External Static Pressures
External Static Pressure (IN. W.C.)
0.2
0.3
0.4
0.5
1680
1635
1585
1545
1425
1385
1335
1290
1255
1215
1160
1115
940
890
835
790
1090
1035
985
940
0.2
0.3
0.4
0.5
2135
2085
2035
1990
1830
1780
1730
1675
1500
1440
1385
1330
1295
1230
1165
1100
1045
965
895
815
LENGTH OF PIPE - FT. (M)
20
120 (37)
250 (76)
200 (61)
465 (142)
375 (114)
950 (290)
770 (235)
1460 (445)
1180 (360)
GAS
SUPPLY
MANUAL
SHUTOFF
VALVE
(REQUIRED)
SEDIMENT
TRAP
UNION
Fig. 18 − Typical Gas Pipe Arrangement
16
0.6
0.7
0.8
1505
1455
1405
1245
1200
1160
1070
1025
975
740
675
620
895
845
790
0.6
0.7
0.8
1935
1880
1825
1625
1575
1520
1275
1220
1170
1045
985
925
745
650
595
30
40
97 (30)
82 (25)
170 (52)
320 (98)
660 (201)
580 (177)
990 (301)
900 (274)
0.9
1.0
1355
1305
1110
1060
925
870
565
525
730
675
0.9
1.0
1770
1715
1470
1420
1115
1055
845
780
540
480
50
73 (22)
151 (46)
285 (87)
A02035