Connecting The Pipes Between The Indoor/Outdoor Unit; Connecting The Drain Hose; Installation - Carrier Klarwind User/Install Manual

Carrier standing type inverter
Table of Contents

Advertisement

Installation

1
When you install the gas pipe horizontally, make sure you form a 1/250 down
gradient (2cm down for a length of 5m) to facilitate refrigerant flows.
2
Insulate the liquid and gas pipes. If you combine the liquid and gas pipes for
insulation, then heat exchanges between them will degrade the compressor
performance significantly.
wire
liquid pipe

Connecting the pipes between the indoor/outdoor unit

How to connect the pipe.
1
Use a flare connection method which is simple and quick.
As shown in the figure below, make a flare at the pipe end and fix the flare nut to
the valve for the indoor and outdoor unit.
2
Flare specification
A

Connecting the drain hose

● Connect the extended drain hose
to the drain hose in the bottom of the unit.
(no leakage allowed.)
insulation
D
vinyll tape
gas pipe
insulation
Outer
diameter
Liquid
6.35
8.3~8.7
12.7
15.4~15.8
Gas
15.88
18.6~19
User / Install Manual
A
Pre-filter
ifD filter
Drain hose
35