3. Configuration

Each UDS is configured using the DeviceInstaller program supplied by Lantronix.
IMPORTANT
1. It is an absolute requirement for the error free operation of the UDS that static IP addresses are
used.
2. The DeviceInstaller program must be run on the same subnet as the UDS device. For example, if
there is a router between the PC running DeviceInstaller and the UDS then the configuration
process will not work.

3.1 DeviceInstaller Configuration

Notes
1. The procedure carried out in this section has to be performed before Telnet Configuration (see
Section 3.2) can be carried out.
2. Make a note of the MAC Address of the UDS (printed on the underside of the UDS or on the cover
above the IP unit of the K2200IP).
3. Consult your IT department to determine the IP Address and the PC Network Class for the UDS.
Procedure
1.
Run the DeviceInstaller program and the DeviceInstaller window is displayed:
2.
Select
and the Assign IP Address window is displayed:
3.
Enter the MAC Address of the UDS, IP Address to be assigned, and PC Network Class.
4.
Select the Set IP Address and the Information window is displayed:
4
17553v1.0