12. CCD Linearity Check
Data picking is done to keep output linearity of the CCD imager,
even if the input level of CCD imager changes.
Mode
STILL (
Subject
Clear chart (Standard picture frame)
Specified value1
97 to 103
Specified value2
97 to 103
Note: If the data of page: 60, address: 02 is "01", select page: 60, address:
01, and write data: 00.
Switch setting:
ZOOM ........................................................................... WIDE end
CAMERA setting (Menu setting) ........................................ AUTO
Adjusting method:
Order Page Address Data
1
2
3
00
01
01
4
75
09
5
75
09
04
6
60
1F
80
7
77
F7
8
77
F7
42
9
77
F2
10
77
F2
02
11
60
14
90
12
60
12
9F
13
14
60
01
F9
15
16
60
E1
17
10
80
18
10
81
19
20
10
82
21
10
83
22
23
60
01
00
24
60
E1
00
25
77
72
26
77
72
30
27
28
60
01
F9
)
Procedure
Check that "1. Data Setting
during Camera System
Adjustments" is performed.
Check the picture frame. If
deviated, perform "4. Picture
Frame Setting".
Set the data.
Read the data, and memorize it.
Write the data.
Write the data.
Read the data, and memorize it.
Write the data.
Read the data, and memorize it.
Write the data.
Write the data.
Write the data.
Wait for 2 sec.
Write the data.
Wait for 2 sec.
Read the data, and check it is "08".
Read the data, and this data is
named D
.
80
Read the data, and this data is
named D
.
81
Calculate D
using the
RG
following equation
(Hexadecimal calculation)
×100 + D
D
= D
RG0
80
81
Read the data, and this data is
named D
.
82
Read the data, and this data is
named D
.
83
Calculate D
using the
BG
following equation
(Hexadecimal calculation)
× 100 + D
D
= D
BG0
82
83
Write the data.
Write the data.
Read the data, and memorize it.
Write the data.
Wait for 2 sec.
Write the data.
Order Page Address Data
29
30
60
E1
31
10
80
32
10
81
33
34
10
82
35
10
83
36
37
60
01
38
60
E1
39
77
72
40
41
60
01
42
43
60
E1
44
10
80
45
10
81
46
47
10
82
48
10
83
49
50
60
01
51
60
E1
52
53
6-23
DSC-P72
Procedure
Wait for 2 sec.
Read the data, and check it is "08".
Read the data, and this data is
named D
.
80
Read the data, and this data is
named D
.
81
Calculate D
using the
RG
following equation
(Hexadecimal calculation)
× 100 + D
D
= D
RGH
80
81
Read the data, and this data is
named D
.
82
Read the data, and this data is
named D
.
83
Calculate D
using the
BG
following equation
(Hexadecimal calculation)
× 100 + D
D
= D
BGH
82
83
00
Write the data.
00
Write the data.
10
Write the data.
Wait for 2 sec.
F9
Write the data.
Wait for 2 sec.
Read the data, and check it is "08".
Read the data, and this data is
named D
.
80
Read the data, and this data is
named D
.
81
Calculate D
using the
RG
following equation
(Hexadecimal calculation)
× 100 + D
D
= D
RGL
80
81
Read the data, and this data is
named D
.
82
Read the data, and this data is
named D
.
83
Calculate D
using the
BG
following equation
(Hexadecimal calculation)
× 100 + D
D
= D
BGL
82
83
00
Write the data.
00
Write the data.
Convert D
, D
, D
RG0
BG0
RGH
D
, D
and D
to decimal
BGH
RGL
BGL
number, and obtain D
RG0
D
', D
', D
' and D
RGH
BGH
RGL
Calculate R/G ratio (H), B/G
ratio (H), R/G ratio (L) and B/G
ratio (L), using the following
equations (Decimal calculation)
R/G ratio (H) =
') ×100
(D
' / D
RGH
RG0
B/G ratio (H) =
') × 100
(D
' / D
BGH
BG0
R/G ratio (L) =
') × 100
(D
' / D
RGL
RG0
B/G ratio (L) =
') ×100
(D
' / D
BGL
BG0
,
', D
',
BG0
'.
BGL