Troubleshooting

Malfunction
No power at the
sensor
Lights do not switch
ON
Lights do not switch
OFF
Lights switch ON
without obvious
movement
Warranty
STEINEL America warrants its products
against defects in material or workmanship
for a period of fi ve years. STEINEL will
replace or repair the item provided that it
has not been altered or subjected to abuse,
accident, improper installation or improper
use. There are no obligations or liabilities
FCC ID - W8J8303
IC - 8529A-8303
This device complies with Part 15 of the
FCC Rules. Operation is subject to the
following conditions:
(1) this device may not cause harmful
interference
M-15103-1
Cause
breaker has tripped; light switch is in
OFF position
short circuit
light level setting is in nighttime
mode during daytime operation
lamp burned out
power is off
detection zone not correctly adjusted
sensor is detecting movement
outside of desired coverage area
sensor is detecting movement
outside of desired coverage area
Remedy
reset breaker, turn light switch
to ON position, check wiring
with voltage tester
check for proper wiring
connections
adjust light level setting
replace lamp
turn power on at circuit breaker
readjust
reduce sensitivity
reduce sensitivity
on the part of STEINEL for consequential
damages arising out of or in connection with
the use or performance of this product or
other indirect damages with respect to loss
of property, revenue, or profi t, or cost of
removal, installation or reinstallation.
(2) this device must accept any
interference received including interference
that may cause undesired operation
(3) Changes or modifi cations not expressly
approved by the party responsible for
compliance could void the user's authority
to operate the equipment
www.steinel.net
(800) 852-4343

Advertisement

loading