Safety Check after Servicing
Examine the area surrounding the repaired location for
damage or deterioration. Observe that screws, parts
and wires have been returned to original positions.
Afterwards, perform the following tests and confirm the
specified values in order to verify compliance with
safety standards.
1. Clearance Distance
When replacing primary circuit components, confirm
specified clearance distance (d) and (d') between sol-
dered terminals, and between terminals and surround-
ing metallic parts. (See Fig. 1)
Table 1 : Ratings for selected area
AC Line Voltage
Clearance Distance (d), (d')
220 to 240 V
Note: This table is unofficial and for reference only.
Be sure to confirm the precise values.
2. Leakage Current Test
Confirm the specified (or lower) leakage current be-
tween B (earth ground, power cord plug prongs) and
externally exposed accessible parts (RF terminals, an-
tenna terminals, video and audio input and output ter-
minals, microphone jacks, earphone jacks, etc.).
Measuring Method : (Power ON)
Insert load Z between B (earth ground, power cord
plug prongs) and exposed accessible parts. Use an
AC voltmeter to measure across both terminals of load
Z. See Fig. 2 and following table.
Table 2: Leakage current ratings for selected areas
AC Line Voltage
220 to 240 V
Note: This table is unofficial and for reference only. Be sure to confirm the precise values.
3mm(d)
6 mm(d')
Load Z
Leakage Current (i)
2kΩ RES.
i≤0.7mA AC Peak
Connected in
parallel
50kΩ RES.
i≤0.7mA AC Peak
Connected in
parallel
Chassis or Secondary Conductor
Primary Circuit Terminals
d'
Exposed Accessible Part
Z
One side of
B
Power Cord Plug Prongs
One side of power cord plug
i≤2mA DC
i≤2mA DC
1-2-4
d
AC Voltmeter
(High Impedance)
prongs (B) to:
RF or
Antenna terminals
A/V Input, Output
T6600SFTY
Fig. 1
Fig. 2