Ctrl-E Analysis
3.2 Commissioning the PLC for SENTRON PAC
References
Additional information about commissioning the PLC can be found in the following references:
CNC Commissioning Manual: NCK, PLC, drive / SINUMERIK 840D sl
3.2.2

SINUMERIK 828D

The PLC of the 828D has a fixed PLC I/O image.
Using the general machine data MD12986[...], the possible peripheral connections (addresses)
are activated or deactivated. When delivered, these addresses are deactivated for the Sentron
devices by entering the address.
Activating the peripheral connection
● SENTRON PAC4200
22
I address
132 ... 135
136 ... 139
140 ... 143
Total active power
(value saved from SENTRON PAC)
Active energy, imported, tariff 1 (instantaneous value)
Active energy, exported, tariff 1 (instantaneous value)
System Manual, 01/2015, 6FC5397-0EP40-5BA2
Ctrl-Energy